2-12. Service Mode Operation

.Page 1 All Reset

(For DXC-D35/D35WS)

PAGE1 (NEXT PREV)

ALL RESET (YES)

DEST : UC

EXIT MENU (YES )

(For DXC-D35P/D35WSP)

PAGE1 (NEXT PREV)

ALL RESET (YES)

EXIT MENU (YES )

Each item value in all FILE can be restored to their standard setting (factory setting).

.Page 2 File Name Change/File Reset

PAGE 2 (NEXT

PREV )

FILE NO.

:

1

FILE NAME

:

 

(STD

)

 

FILE RESET

 

 

(YES

)

FILE NO.

File No. of operation item

FILE NAME

File name of operation item file

FILE RESET

Performing of FILE RESET

EXIT MENU (YES)

.Page 3 File Recall

PAGE3 (NEXT PREV)

FILE RECALL FILE :*HISAT SELECT FILE

STD

CHG FILE (YES )

EXIT MENU (YES)

2-34

FILE

File name which is recalled

SELECT FILE

Select file to be recalled

CHG FILE

Performing of FILE RECALL

DXC-D35/D35WS(UC)

DXC-D35P/D35WSP(CE) V1

Page 96
Image 96
Sony service manual All Reset For DXC-D35/D35WS, File Name Change/File Reset, File Recall