DXC-D35P/D35WSP(CE)

DXC-D35/D35WS(UC)

Viewfinder Screen Adjustments

Adjusting the Lens

V1

The following adjustments are provided to improve the visibility of the viewfinder screen.

Although these adjustment may make the viewfinder image clearer, they have no effect on the output video signal from the camera.

Eyepiece focusing knob

BRIGHT control

CONTRAST control

PEAKING control

OUTPUT/DL/

DCC+ switch

Contrast and brightness adjustment

Carry out these adjustments with the color bars displayed.

1 Set the OUTPUT/DL/DCC+ switch to the BARS position.

The color bars appear in the viewfinder.

2 Watching the color bars, turn the CONTRAST and BRIGHT controls to adjust the contrast and brightness.

3 Return the OUTPUT/DL/DCC+ switch to its original position.

Outline emphasis adjustment

Turning the PEAKING control changes the degree of outline emphasis in the viewfinder image, to make focusing easier.

Flange Focal Length Adjustment

It is necessary to adjust the flange focal length (the

• When a lens is fitted for the first time

distance from the lens flange to the plane of the image

• After changing lenses

along the optical axis) in the following cases.

• When during zoom operations the focus does not

 

 

 

match properly from telephoto to wide angle

4,11

2

1

3

9

 

 

 

About 3 m (10 feet)

 

 

 

Flange focal length

 

 

 

 

adjustment test chart

 

 

T

A

 

RET

W

M

IRIS

 

 

 

 

 

 

 

Chapter 5 Adjustments and Settings

Adjusting the eyepiece focus

Depending on the eyesight of the camera operator — whether longsighted or shortsighted — the optimal position of the viewfinder image varies. Adjust the eyepiece focus to get the clearest viewfinder image for your eyesight. First focus the image with the lens, then adjust the eyepiece focusing knob. The adjustment range is from –3 to 0 diopters1) (default when shipped is 0 diopters).

Using an optional part allows you to modify the adjustment range to –2 to +1 diopters or –0.5 to +3 diopters.

For details, consult your Sony dealer.

..........................................................................................................................................................................................................

1)Diopter: A unit to indicate the degree of convergence or divergence of a bundle of rays.

88

Chapter 5 Adjustments and Settings

 

8

6

7

5

 

 

 

 

 

 

 

ZOOM

 

 

 

 

 

SERVO

MANU.

 

1

Set the iris selector to the M position.

 

 

7 Turn the focusing ring so that the test chart is in

Chapter 5

 

 

Adjustmentsand

3

Place the supplied flange focal length adjustment

 

position.

2

 

 

 

 

focus.

 

Turn the iris ring to f/1.8 (fully open).

 

 

8 Move the manual zoom control to the wide angle

 

 

 

 

 

 

Settings

 

adjust the lighting so that an appropriate video

 

9 Turn the F.B adjustment ring so that the test chart

 

test chart at a range of about 3 meters (10 feet), and

 

 

 

output level is obtained with the iris at f/1.8.

 

 

is in focus. Do not move the focusing ring.

 

4

Loosen the F.B fixing screw.

 

 

10Repeat steps 6 to 9 until the image stays in focus

 

5

 

 

 

 

from telephoto to wide angle.

 

Set the ZOOM selector to the MANU. position.

 

11After adjustment, tighten the F.B fixing screw.

 

6

Move the manual zoom control to the telephoto

 

 

 

 

 

position.

Chapter 5 Adjustments and Settings

89

1-45

Page 53
Image 53
Sony DXC-D35 service manual Viewfinder Screen Adjustments Adjusting the Lens, Contrast and brightness adjustment, Position