3.Adjust the lens iris to bring the white level “A” to 70
± 2 IRE.
Test point: VIDEO OUT connector
4.In the following items, by pressing the UP or DOWN switches, adjust the waveform of the oscilloscope to be flat.
GND:
Item | Test point | Specification |
R W. SHAD | CL101 |
|
|
|
|
G W. SHAD | CL201 |
|
|
|
|
B W. SHAD | CL301 |
|
5.If the lens has an extender, set the extender ON and perform the adjustment of step 4.
3-3-14. Flare Adjustment
Object: | Grayscale chart |
Equipment: | Waveform monitor |
Preparation: |
|
.OUTPUT/DL/DCC +switch: CAM/DCC +
.Select a large lens iris and shoot the grayscale chart covering fully the underscanned frame.
(Refer to Section
Test point: VIDEO OUT connector
Adjustment Procedure
1. SERVICE menu “PAGE 3”
→R FLARE: x
G FLARE: 5
B FLARE: x
n
Make sure that “G FLARE” is “5”.
2.Push the WHT/BLK switch in the “BLK” direction to make a black balance.
3.Adjust the lens iris to bring the white level to A = 100 IRE.
4.With the W. BAL switch set to “A”, push the WHT/ BLK switch in the “WHT” direction to make a white balance.
H
G
FE
1
2
3
4
5.Make the lens iris large by two steps.
6.Adjust the flare with UP and DOWN switches alternatively to minimize the carrier leakage level.
CL301 CL101 CL201
5
6