DXC-D35P/D35WSP(CE)

DXC-D35/D35WS(UC)

Viewfinder Advanced Menu

Bring up the advanced menu pages by setting the POWER switch to ON while pressing the UP/ON button up (see page 52).

Advanced menu page 1

Use this page to return all advanced menu settings to

Advanced menu page 3

Advanced menu page 4

There are up to 15 advanced menu pages (the number displayed depends on the switch settings and the type of connected VTR).

Note on EZ mode

their factory preset values.

For details of this operation, see “Displaying the advanced menu and switching to the normal indications” (page 52).

a)

￿

cPAGE4 (NEXTcV PREVcv)￿

￿

 

 

 

MARKER

: CENT/90%￿

LIMITS

: OFF￿

 

ZEBRA

:

1 ￿ a)

 

ZEBRA1

: 70IRE

￿

￿

 

 

 

VF S DTL: ± 0￿

 

VF TALLY:

× 2￿

 

VF PLAY

:

Y￿

 

When the camera is in EZ mode, the advanced menu does not appear. Release the EZ mode beforehand. (See page 14.)

Advanced Menu Operations

To change the page

Move the cursor to the menu number, then press the UP/ON button or the DOWN/OFF button.

Pressing the UP/ON button displays the previous page and pressing the DOWN/OFF button displays the next

Advanced menu page 2

a) For DXC-D35P/D35WSPL: EBU75

Item

Settings

AWB MEM

2 (normal value): No

Selects whether or not to

correspondence with FILTER

make the FILTER knob

knob settings. Only two

settings (1 to 4) correspond

adjustment values (A and B)

to separate white balance

are stored in memory.

adjustment values stored in

2 × 4FL: Correspondence

memory.

with FILTER knob settings.

 

Each of the four knob

 

settings can be used to set A

 

and B adjustment values, for

 

a total of eight settings.

TONE

ON (normal value): Output

Selects whether or not to

audio signal.

output a 1-kHz audio signal

OFF: Do not output audio

LENS SEL:

1￿

￿

 

EXIT MENU (YEScv)

a) For DXC-D35P/D35WSPL: 70%

Item

Settings

MARKER

CENT/90% (normal value):

Selects ON/OFF setting for

Displays center marker and

center marker, size setting

safety zone marker at 90%

(percentage of viewfinder

size.

screen area), and display

CENT/80%: Displays center

ON/OFF setting.

marker and safety zone

 

marker at 80% size.

 

90%: Displays only safety

 

zone marker at 90% size.

 

80%: Displays only safety

 

zone marker at 80% size.

 

CENT: Displays only center

 

marker.

Chapter 4 Viewfinder Screen Indications and Menus

page. Pressing the DOWN/OFF button when the last page is being displayed returns the display to the first page.

To select items in a page

Press the MENU/STATUS switch to move the cursor among the menu items.

To change settings

This operation is the same as for the basic menus.

For a description of basic menu operations, see page 58.

To return to the normal indications

Move the cursor to EXIT MENU, then press the UP/

Item

Settings

GAIN

This sets gain values for the positions of the GAIN switch. The HIGH, MID, and LOW values must be set so that LOW < MID < HIGH.

LOW

–3 dB, 0 dB (normal

Sets the L position.

value), 3 dB, 6 dB, 9 dB, 12

 

dB, 18 dB, 18 dB + DPR, 24

 

dB

MID

0 dB, 3 dB, 6 dB, 9 dB

Sets the M position.

(normal value), 12 dB, 18

 

dB, 18 dB + DPR, 24 dB, 24

 

dB + DPR

HIGH

3 dB, 6 dB, 9 dB, 12 dB, 18

Sets the H position.

dB (normal value), 18 dB +

 

DPR, 24 dB, 24 dB + DPR,

with the color bars when the

signal.

OUTPUT/DL/DCC+ has

 

been set to BARS.

 

BARS

SMPTE (normal value for

Selects normal width or

DXC-D35/D35WSL):

narrower width for color

Normal width

bars.

EBU75 (normal value for

 

DXC-D35P/D35WSPL): EBU

 

75%

 

EBU100 (for DXC-D35P/

 

D35WSPL): EBU 100%

 

SPLIT (for DXC-D35P/

 

D35WSPL): Not for normal

 

operation

 

SNG: Narrower than normal

 

(used for satellite

 

communications, etc.)

REMOTE1

REC (normal value):

Sets a function for position 1

Specifies recording start/stop

of a switch connected to the

MARK: Specifies a Mark IN/

REMOTE1 connector.

OUT point.

 

CUE: Specifies a cue point.

 

NG: Specifies NG/OK.

LIMITS (For DXC-D35WSL/ D35WSPL)

Selects the safety zone size when the scan size is 16:9.

ZEBRA

Selects type of zebra pattern display.

ZEBRA1

Sets base level for zebra pattern 1.

OFF (normal

value):FDepends on the scan size.

4:3, 13:9, 14:9, 15:9

1 (normal value): Displays the zebra pattern over parts having a video level. between 70 and 90 IRE (or 70 and 90%).

Use the next item (ZEBRA1) to select the base level.

2:Displays the zebra pattern over parts having video levels of 100 IRE or above

( or 100% or above). 1/2: Dual display (both 1 and 2)

70 IRE (normal value) to 90 IRE or 70% (normal value) to 90%

Can be set for each IRE step or 1% step.

Chapter 4 Viewfinder Screen Indications and Menus

ON button.

Contents and Settings of Each Page

Each page’s contents and settings are described below.

64 Chapter 4 Viewfinder Screen Indications and Menus

 

HYPER GAIN

HYPER

36 dB (normal value), 42

Sets gain value when the

dB

HYPER GAIN is selected.

 

DL

ON (normal value), OFF

Sets DynaLatitude function

When set to ON, the amount

ON/OFF.

of DynaLatitude effects is

This setting is valid only

set in basic menu page 3

when the OUTPUT/DL/

(see page 59).

DCC+ switch has been set to

 

DL.

 

REMOTE2

REC: Specifies recording

Sets a function for position 2

start/stop.

of a switch connected to the

MARK (normal value):

REMOTE1 connector.

Specifies a Mark IN/OUT

 

point.

 

CUE: Specifies a cue point

 

NG: Specifies NG/OK.

BAUD RATE

9600, 38400 (normal value)

Sets a baud rate for a

 

computer connected to the

 

REMOTE connector 2 (to be

 

supported in future version).

 

VF S DTL

–99 to ±0 (normal value) to

Sets the detail level of

+99

images on the viewfinder

Negative values set softer

screen (displayed only when

edges and positive values

a viewfinder other than the

set sharper edges.

DXF-701/701CE/701WS/

 

701WSCE/801/801CE is

 

attached).

 

 

(continued)

Chapter 4 Viewfinder Screen Indications and Menus 65

1-33

Page 41
Image 41
Sony DXC-D35 service manual Advanced Menu Operations, Advanced menu, To change, To return to the normal indications