.Page 18 FILTER Display Setting
PAGE18 (NEXT PREV)
FILTER1 | : 3200 |
FILTER2 | : 5600+1/8ND |
FILTER3 | : 5600 |
FILTER4 | : 5600+1/64ND |
EXIT MENU (YES )
.Page 19 Self Diagnosis 1
PAGE19 (NEXT PREV )
DIAG ERROR RESET (YES)
MEMORY BACKUP (YES)
EXIT MENU (YES)
FILTER 1 to 4
Make this setting in accordance with a kind of filter attached.
n
When changing the filter, be sure to make a set.
DIAG ERROR RESET
This item is used for erasing an error check results and a history of error items.
MEMORY BACKUP
This item is used when back up the EEPROMs data on the TG, IF, and ES boards to EEPROM on the MB board.
n
Backup is needed when the TG, IF, or ES board has been replaced.
[Reference]
If there is a communication error between the TG, IF, or ES board’s EEPROM and microcomputer when the power is turned on, the backed up data in EEPROM on the MB board is used.
The “DIAG ERROR RESET” and “MEMORY BACKUP” will be also carried out when the RESET in Service Menu Page 1 is execut- ed.