Item | Test Point | Specification |
| |
Y LEV | TP61 | NTSC: A = 714 ±10 mV | ||
|
|
| F = 54 ±5 mV | |
|
| PAL: | A = 700 | ±10 mV |
*W Y LEV | TP61 | NTSC: A = 714 | ±10 mV | |
|
| PAL: | A = 700 | ±10 mV |
3-3-5. Carrier Balance Adjustment
Equipment: Verctorscope (MAX GAIN)
Preparation: OUTPUT/DL/DCC +switch: BARS
Test point: VIDEO OUT connector
SYNC LEV | TP61 |
(NTSC)
F
NTSC: B = 286 ±5 mV
PAL: B = 300 ±5 mV (PAL)
AA
B B
Adjusting point
1.SERVICE menu “PAGE 7”
→
2.Adjust by the UP switch or DOWN switch to bring the beam spot of the black level in the center of the vectorscope.
TP60 | NTSC: C = 700 | ± 20 mV | ||||
|
| PAL: | C = 525 | ± 20 mV | ||
*W | TP60 | NTSC: C = 700 | ± 20 mV | |||
|
| PAL: | C = 525 | ± 20 mV | ||
|
|
|
|
|
|
|
C
TP62 | NTSC: D = 700 | ± 20 mV | ||||
|
| PAL: | D = 525 | ± 20 mV | ||
*W | TP62 | NTSC: D = 700 | ± 20 mV | |||
|
| PAL: | D = 525 | ± 20 mV | ||
|
|
|
|
|
|
|
D
| [for NTSC] |
| [for PAL] |
|
| MG |
| R |
|
| R |
| MG | |
|
|
|
| |
YL |
| YL | 75% |
|
|
|
| ||
| 100% |
|
|
|
| 75% |
|
| B |
| B |
|
| |
G | CY | G | CY |
|
|
|
|
*: