PROBLEM | CAUSE | CORRECTION | ||
|
|
|
|
|
Motor will | • | Check valve is | • | Remove and clean, or replace. |
not run. |
| stuck open. |
|
|
(con’t) | • | Loose electrical | • | Check wiring connection inside |
| ||||
|
| connections. |
| pressure switch and terminal box |
|
|
|
| area. |
| • | Possible | • | Return to an Authorized Warranty |
|
| defective |
| Service Center for inspection or |
|
| capacitor. |
| replacement if necessary. |
•Paint spray on • Have checked at an Authorized
internal motor Warranty Service Center. Do not
parts.operate the compressor in the paint
| spray area. See flammable vapor |
| warning. |
• Possible | • Have checked at an Authorized |
defective | Warranty Service Center. |
motor. |
|
•Fuse Blown, 1.Check fuse box for blown fuse and
circuit breaker replace. If necessary, reset circuit
tripped.breaker. Do not use a fuse or circuit
breaker with higher rating than specified for your particular branch circuit.
|
| 2.Check for low voltage conditions |
|
| and/or proper extension cord. |
|
| 3.Disconnect the other electrical |
|
| appliances from circuit or operate |
|
| the compressor on its own branch |
|
| circuit. |
| • Pressure | • Bleed the line by pushing the lever |
| unloader valve | on the pressure switch to the "off" |
| on pressure | position; if the valve does not open, |
| switch has not | replace it. |
| unloaded head |
|
| pressure. |
|
|
|
|
Regulator | Dirty or damaged | Replace regulator. |
knob has | regulator internal |
|
continuous | parts. |
|
air leak. |
|
|
Regulator |
|
|
will not |
|
|
shut off at |
|
|
air outlet. |
|
|
Page 16