INSTALLATION AND | OWNERS MANUAL |
INSTALLATION AND BREAK-IN PROCEDURES ... Cont’d
CAUTION:
Initial Start Up Procedure:
1)Open the air receiver's drain valve.
2)Plug power supply cord into correct power source.
3)Run the compressor for a minimum of twenty (20) minutes in the
4)Close air receiver drain valve. Your compressor is now ready for use.
Extension Cords:
To avoid voltage drop, power loss, and overheating of the motor, use extra air hose instead of an extension cord. Low voltage can cause damage to the motor.
If an extension cord must be used:
Use only an approved
Make sure the extension cord is in good condition.
Please see the chart below as the MINIMUM requirements:
Amp Rating |
| Length of cord in feet |
| |
|
|
|
|
|
(120 volts) | 25’ | 50’ | 100’ | 150’ |
|
|
|
|
|
10 - 12 | 16 | 14 | 10 | 8 |
|
|
|
|
|
12 - 14 | 16 | 12 | 10 | 8 |
|
|
|
|
|
14 - 16 | 16 | 12 | 10 | 8 |
|
|
|
|
|
16 - 18 | 14 | 12 | 8 | 8 |
|
|
|
|
|
18 - 20 | 14 | 12 | 8 | 8 |
|
|
|
|
|