Makita MAC5200 Operating Procedures, Piping, Grounding Instruction, Do not USE AN Adapter

Page 11

OWNERS MANUAL

OPERATING PROCEDURES

INSTALLATION AND BREAK-IN PROCEDURES ... Cont’d

Piping:

Plastic or PVC pipe is not designed for use with compressed air. Regardless of its indicated pressure rating, plastic pipe can burst from air pressure. Use only metal pipe for air distribution lines. If a pipe line is necessary, use pipe that is the same size, or larger than, the air tank outlet. Piping that is too small will restrict the flow of air. If piping is over 100 feet long, use the next larger size. Bury underground lines below the frost line and avoid pockets where condensation can gather and freeze. Apply pressure before underground lines are covered to make sure all pipe joints are free of leaks.

Grounding Instruction:

WARNING: Risk of electric shock!

In the event if a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances. The outlet must have the same configuration as the plug.

DO NOT USE AN ADAPTER.

Inspect the plug and cord before each use. Do not use if there are signs of damage.

DANGER: Improper grounding can result in electrical shock. Do not modify the plug that has been provided. If it does not fit the available outlet, the correct outlet should be installed by a qualified electrician.

OPERATING PROCEDURES

Daily Start-Up Checklist:

1)Before attaching air hose or accessories, make sure the pressure switch lever is set to “OFF” and the air regulator or shut-off valve is closed.

2)Attach hose and accessories. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer's maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

3)Turn the pressure switch lever to “ON/AUTO” and allow tank pressure to build. Motor will stop when tank pressure reaches “cut-out” pressure.

4)Open the regulator by turning it clockwise. Adjust the regulator to the correct pressure setting. Your compressor is ready for use.

5)Always operate the air compressor in well-ventilated areas; free of gasoline or other solvent vapors. Do not operate the compressor near the spray area.

MAKITA - MAC700 / MAC2400 / MAC5200

11

Image 11
Contents Model no MAC700 MAC2400 MAC5200Table of Contents Operation Safety InstructionsRisk of Unsafe Risk of Attachments AccessoriesRisk of Air Tank BurstingRisk to Breathing Risk of Electric ShockRisk of Explosion or FireRisk of Burn Risk fromCompressed Air Moving PartsGeneral Information CUT-OUT Pressure When you turn onGlossary Duty Cycle Description of Operation On Receipt Inspection Storage Lubrication and OIL Installation and BREAK-IN ProceduresDescription of Operation Location of the AIR Compressor25’ 50’ 100’ 150’ Installation and BREAK-IN Procedures ... Cont’dInitial Start Up Procedure Extension CordsGrounding Instruction Operating ProceduresDaily Start-Up Checklist PipingWhen you are finished Operating ProceduresMaintenance Filling with oil Routine Maintenance ScheduleEach year of operation or if a problem is suspected Cold Weather ConditionsMotor Service InstructionsAir Filter Inspection and Replacement Units with External Brass Check Valve ReplacementDo not Over Tighten Troubleshooting GuideProblem Cause Correction Problem Cause Correction California Makita Retain this Portion for Your RecordsMakita MAC700 / MAC2400 / MAC5200 Makita Corporation Makita Limited ONE Year WarrantyWarranty Policy Your answers to the following questions are appreciated Mail this PortionMakita U.S.A., Inc