Craftsman 919.176830, 919.176730, 919.17673g Operating Procedures, Grounding nstructions

Page 9

Grounding _nstructions

iMPROPER GROUNDING CAN RESULT tN

ELECTRICAL SHOCK= IN THE EVENT OF A

SHORT CIRCUIT, GROUNDING REDUCES THE RiSK OF SHOCK BY PROViDiNG AN ESCAPE WiRE FOR THE ELECTRIC CUR-

RENT, THIS A_R COMPRESSOR MUST BE PROPERLY GROUNDED.

1.The air compressor is equipped with a cord having a grounding wire and an appropriate grounding plug= The plug must be used with an outlet that has been

installed and grounded in accordance with alt local codes and ordinances. The outlet must have the

same configuration as the plug. DO NOT USE AN ADAPTER.

2.Do not modify the plug that has been provided. If it does not fit the available outlet, the correct outlet

should be installed by a qualified electrician.

3.Inspect the plug and cord before each use. Do not use the compressor if there are signs of damage.

ELECTRICAL SHOCK HAZARD. WHEN REPAmRING OR REPLACING THE CORD OR

PLUG, KEEP THE GROUNDING W_RE SEPA- RATE FROM THE CURRENToCARRYmNG

W_RES. NEVER CONNECT THE GROUND- gNG W_RE TO A FLAT BLADE PLUG TER=

MINAL, (THE GROUNDING W_RE HAS INSULATION WITH AN OUTER SURFACE THAT IS GREEN - WSTH OR W_THOUT YEL- LOW STRIPES.)

If these grounding instructions are not completely understood, or if you are not sure your compressor is property grounded, have the installation checked by a qualified electrician.

OUTLETPLUG

Terminal

G_'ounding]/

Pin//

Breakqn Procedures

Serious damage may result if the following

break=in instructions are Rot closely followed.

This procedure is required only once, before the air com- pressor is put into service.

1.Set the pressure switch lever to the "OFF" position. 2, Plug the power cord into the correct branch circuit

receptacle.

3.l_drnthe regulator clockwise opening it fully, to prevent air pressure build-up inthe tank.

4.Move the pressure switch lever to "ON/AUTO". The compressor witl start.

5.Run the compressor for 30 minutes. Make sure the regulator is open and there is no tank pressure build-

up.

6.After 30 minutes, close the regulator by turning it counter-clockwise. The air receiver wilt filt to cut-out

pressure and the motor wilt stop. The compressor is now ready for use.

OPERATING PROCEDURES

1.Before attaching an air hose or accessory', make sure the pressure switch lever is in the "OFF" posi-

tion. Close the air regulator outlet by turning it counter-clockwise.

TOO MUCH AmR PRESSURE CAUSES A HAZARDOUS R_SK OF BURSTING, CARE_ FULLY FOLLOW STEPS 3 THROUGH !2 EACH TmMETHE COMPRESSOR IS USED,

3.Check the manufacturer's maximum pressure rating for air tools and accessories. The reguator outlet pressure must never exceed the maximum pressure rating.

Compressed air from the outfit may certain

water condensation and oH mist. Do not spray uRfi_tered air at aR item that coutd be

damaged. Some air operated toots or devices may require filtered air, Read the

4, ]_Jrnthe pressure switch lever to the "ON-AUTO"position and allow tank pressure to build. The motor win stop when tank pressure reaches cut-out pressure.

5.Open the regulator by turning it clockwise. Adjust the regulator to the correct pressure setting. (See pg. 6

for regulator instructions.) Your outfit is ready for use.

When You Are F_nished:

6.Set the pressure switch lever to "OFF".

7.qFdrnthe regulator counter-clockwise and set the out- let pressure to zero.

8.Remove the air tool or accessory.

9.Open the regulator and allow the air to sowly bleed from the tank. C_ose the regulator when tank pres _

sure is approximately 20 psi.

10. Drain water from air tank.

s

Image 9
Contents Sears, Roebuck and Coo, Chicago, IL 60684 U.S.A SFA/RSTable of Contents Njury or Loss of Life Safety GUiDELiNESNOW to Prevent T WhattoCFM GlossaryAsme ScfmGeneral iNFORMATiON Accessories for USE WiTH Sears CompressorsPressure Assembly InstructionsTotems You WiN Need To Assemble Your Jnstamling NandmeMnstagJiag Rubber Foot Strip and Wheels Nstallatjon and BREAK= N ProceduresNataHing Tank Pressure Gauge Location of the Air CompressorGrounding nstructions Operating ProceduresElectrical SHOCK= in the Event of a RENT, this AR Compressor Must be Properly GroundedCheck Valve Replacement MaintenanceSafety Valve nspection Air CompressorProblem Bet ReplacementStorage Pulley and Flywheem = AlignmentWeaken Cause CorrectionTighten Troubleshooting Guide Cause51A Od Ill p ugl Dra,n plug Compressor Pump Dagram265-18 Parts LiST68 265=196 Sears, Roebuck and Co., Chicago, L 60684 U.SoAo Craftsman AIR Compressor

919.176830, 919.17683, 919.17673g, 919.176730 specifications

The Craftsman 919.176730, 919.17673G, 919.17683, and 919.176830 are a series of versatile and highly efficient air compressors designed to meet the demands of both DIY enthusiasts and professional contractors. Known for their reliability and performance, these models offer a range of features and technologies that cater to a wide variety of tasks.

One of the standout features of these air compressors is their powerful motor, which delivers impressive horsepower for efficient air delivery. The 919.176730 and its counterparts come equipped with an exceptionally durable pump, often oil-lubricated, providing longevity and reduced wear over time. This characteristic is crucial for those who require a dependable tool for continuous use.

The compressors boast a user-friendly design, featuring easy accessibility to vital components for maintenance. This is complemented by an intuitive control panel that allows for straightforward adjustments and monitoring of pressure levels—essential for users who need precise control for different applications. The large capacity tanks, typical in models like the 919.17683 and 919.176830, allow for extended operation without frequent cycling, making them ideal for tasks such as spray painting, powering nail guns, and other pneumatic tools.

Another key aspect is the portability of these models. Most are designed with durable wheels and rugged handles for easy transport, enabling users to move the compressor between job sites or around the home with minimal effort. This feature does not compromise stability or performance, as they are built to withstand the rigors of diverse working environments.

Safety features abound in the Craftsman air compressors as well. Each unit is designed with built-in thermal overload protection, which automatically shuts off the machine if it becomes too hot, ensuring user safety and preventing damage to the compressor. Additionally, the integrated pressure gauges provide real-time feedback on air levels, preventing over-inflation of tools and accessories.

In terms of noise levels, these compressors are engineered to operate more quietly than many traditional models, making them suitable for residential use without disturbing neighbors. This focus on user comfort is a testament to Craftsman's commitment to providing effective and customer-friendly solutions.

In summary, the Craftsman 919.176730, 919.17673G, 919.17683, and 919.176830 air compressors are remarkable tools that combine power, durability, and safety features. With their advanced technologies and thoughtful design, they stand out as excellent choices for anyone looking to enhance their tool collection. Whether for hobby projects or professional work, these compressors deliver reliable performance time and again.