Xantrex Technology HW 1000 manual Breaker Size, Minimum Wire Size

Page 21

Basic Installation Procedures

AC breakers and fuses must be sized to adequately protect the wiring that is installed on the input and output AC circuits of the Freedom HW. All breakers and wiring must be sized and connected in accordance with the electrical codes or regulations applicable to your installation. Table 1-1gives some examples of wiring sizes based on the U.S. National Electrical Code and the Canadian Electrical Code. These examples are based on using a 2-conductor-plus-ground cable rated at 75 °C, and assuming an ambient temperature of up to 30 °C. Ensure that your breakers, and fuses have suitable temperature ratings for your wiring. Other codes and regulations may also be applicable to your installation.

Table 1-1Required AC Wire Size vs Breaker Rating

 

Breaker Size

15A

20A

30A

 

Minimum Wire Size

14AWG

12AWG

10AWG

 

 

 

 

 

 

 

AC Output

The neutral conductor of the Freedom HW’s AC output circuit (i.e., AC

Neutral

Output Neutral) is automatically connected to the safety ground during

Bonding

inverter operation. When the Freedom HW is using AC shore power, this

 

connection is not present, so that the utility neutral (i.e., AC Input

 

Neutral) is only connected to utility ground at your source. This conforms

 

to National Electrical Code, which requires that separately derived AC

 

sources (such as inverters and generators) to have their neutral conductors

 

tied to ground in the same way that the neutral conductor from the utility

 

is tied to ground in only one place. Check the regulations for your specific

 

application to ensure that the installation will comply with the necessary

 

requirements. In other words, the AC Input Neutral and Output Neutral

 

must be isolated from each other.

 

 

 

DC Cabling

This includes all the cables and connectors between the batteries, the DC

 

disconnect and over-current protection device, and the Freedom HW.

 

Most mobile installations require multi-strand insulated cables for

 

flexibility and durability in high vibration environments and require

 

disconnects and over-current devices. Electrical wiring sizes are indicated

 

by AWG notation. Under the AWG standard, a larger gauge number

 

indicates a smaller wire diameter. Wire size is usually marked on the

 

larger sized cables. Table 1-2specifies the minimum recommended DC

 

cable size and maximum fuse size for the Freedom HW. The DC cables

 

must be copper and must be rated 75 °C minimum. The cables should

 

be terminated with lugs that fit the DC stud terminals snugly (8 mm or

 

5/16 in. hole size).

 

 

 

 

 

 

 

 

 

 

975-0468-01-01

 

 

 

 

1–9

This guide for use by qualified installers only

Image 21
Contents Freedom HW Page Freedom HW 1000 Inverter/Charger Contact Information Date and RevisionScope PurposeAudience OrganizationRelated Information Conventions UsedImportant Safety Instructions 975-0468-01-01 Personal Precautions When Working With Batteries DC Connection Precaution Contents Electrical Specifications Inverter Mode SpecificationsInstallation 1What’s In The Box Materials ListInstallation Codes Safety InstructionsHigh Level Overview of Installation Steps Installation Tools and MaterialsBasic Installation Procedures To engine Designing the InstallationHW system Carry the current rating of the individual AC output breaker Breaker Size Minimum Wire SizeMinimum Cable Size Inverter/ChargerBasic Installation Procedures Choosing a Location for the Freedom HW To mount the Freedom HW Mounting the Freedom HWApplication Stranded cable is recommended Minimum equipment ground cable sizeGeneral AC Wiring Considerations Connecting the AC Input WiresFreedom HW Color AC Wire5Freedom HW AC Wiring Compartment Make Model Connecting AC Output to an Existing AC CircuitBasic Installation Procedures 975-0468-01-01 6AC Wiring Diagram with an Inverter Subpanel 7AC Wiring Diagram without an Inverter Subpanel 8shows the DC end for your reference Connecting the DC CablesTo make the DC connections Basic Installation Procedures DC Grounding To mount the display panel Mounting the Display PanelTesting in Invert Mode Testing Your InstallationTesting in Shore Power Mode Page Specifications DC Input Electrical Specifications Inverter ModeAC Output OtherElectrical Specifications Charge Mode AC InputDC Output System Specifications Environmental SpecificationsPhysical Specifications Unit Dimensions and WeightInverter Overload Operation Regulatory ApprovalsInvert Power Derating vs. Ambient Temperature 1Charging Voltage Charger Output Current vs. AC Input VoltagePage Page Xantrex Technology Inc
Related manuals
Manual 80 pages 1.39 Kb

HW 1000 specifications

Xantrex Technology HW 1000 is a well-regarded power inverter designed to meet the needs of recreational vehicle (RV) enthusiasts, marine applications, and off-grid solar systems. With its robust design and advanced technology, the HW 1000 offers an optimal solution for transforming DC power into reliable AC power, making it an essential component for anyone who requires off-grid energy solutions.

One of the main features of the Xantrex HW 1000 is its ability to deliver a continuous output of 1000 watts with a peak surge capability of up to 2000 watts. This means it can handle high inrush currents needed by appliances like refrigerators and air conditioners, providing a reliable power supply, even during demanding operations. The inverter is equipped with a pure sine wave output, which is crucial for sensitive electronics, ensuring that devices operate smoothly without the risk of damage or interference.

The HW 1000 employs advanced technology to detect and eliminate any harmonic distortion, giving users clean and stable power for any application. The inverter features built-in safety mechanisms such as over-voltage, under-voltage, and thermal overload protection, which safeguard both the unit and the devices connected to it. This robust protection ensures longevity and reliable operation, even in challenging conditions.

Portability is another key characteristic of the Xantrex HW 1000. Compact and lightweight, it can be easily transported in an RV, boat, or even a truck bed. The inverter is designed for easy installation, with a user-friendly interface that includes LED indicators for battery status, output voltage, and fault alerts, allowing users to monitor performance easily.

The HW 1000 is versatile and can be used in various applications, making it ideal for both recreational and emergency situations. It can power tools for construction work in remote locations, support essential appliances during power outages, or even charge batteries in solar setups, showcasing its adaptability across different energy needs.

In summary, the Xantrex Technology HW 1000 is a powerful, efficient, and versatile power inverter packed with essential features that ensure reliable performance for a wide range of applications. Its lightweight design, safety features, and pure sine wave output make it a popular choice among outdoor enthusiasts, tradespeople, and anyone looking for a dependable power solution.