Studer Innotec C 1600-12, C 2600-24, C 4000-48 Light Emitting Diodes, Push buttons, Turning Knobs

Page 13

STUDER INNOTEC

COMPACT

4.2Light Emitting Diodes

 

LED

 

Marking

LED lit

 

 

 

LED blinks

 

1

 

AC IN

Voltage corresponding to self-

Voltage, outside of the self-

 

 

 

 

adjusted values is at the AC IN

adjusted values is at the AC IN

 

 

 

 

input.

 

 

 

input.

 

2

 

CHARGER

Battery Charger is working

 

The input voltage is out value

 

 

 

 

 

 

 

 

(voltage or frequency)

 

3

 

SOLAR

Connected

solar modules

are

 

 

 

 

CHARGE

delivering energy

 

 

 

 

4

 

Program

Programming

mode

for

Aux.

 

 

 

 

 

Contact

 

 

 

 

 

5

 

Contact active

Auxiliary Contact is activated

 

 

 

6

 

Contact manual

Aux. Cont. manually activated

 

 

 

7

 

 

Transfersystem is active. In-

 

 

 

 

 

coming voltage is being sent

 

 

 

 

 

directly to AC OUT outlet

 

 

 

8

 

AC OUT

There is voltage at the AC OUT

The Inverter is in Standby-Mode

 

 

 

 

outlet

 

 

 

 

 

9

 

INVERTER

Inverter is working

 

 

Forced -Inverter Mode

 

10

 

Over Temp.

For the time being the COMPACT

 

 

 

 

 

is out of service because of

 

 

 

 

 

overheating.

 

 

 

 

 

11

 

Overload

The COMPACT is out of service

 

 

 

 

 

because of overload or short-

 

 

 

 

 

circuit

 

 

 

 

 

12

 

Batt. Low/High

Battery voltage is too low

 

Battery voltage is too high

 

13

 

OFF

COMPACT is turned off. Turning it

COMPACT is for the time being

 

 

 

 

back on is only possible manually.

turned off. Turning it back on will

 

 

 

 

 

 

 

 

follow automatically!

 

14

 

 

Battery Charger and

or Solar

 

 

 

 

 

Charge Controller are doing an

 

 

 

 

 

equalization cycle

 

 

 

 

15–18

 

Charge condition of Battery

 

LED 15 – Absorption time is

 

 

 

 

 

 

 

 

running

 

25

 

CURRENT

Display the value of the output power in % of Pnom (in Inverter Mode)

 

 

 

MONITOR

and the charge current in Amps. (in Charger Mode) In this mode the

 

 

 

 

200% LED indicate that power sharing is in use.

4.3

Push buttons

 

 

 

 

 

 

 

 

 

 

19

 

ON/OFF

Turning the COMPACT on and off (Help Button for Programming)

 

20

 

RESET

Alarm Signal off (Help Button for Programming)

 

21

 

Aux. Contact

Control Aux. contact (Help Button for Programming)

4.4

Turning Knobs

 

 

 

 

 

 

22

 

CHARGER

Adjustment for max. Charging Current (Not for Solar charge controller)

 

23

 

TRANSFER

Adjustment for Transfer Voltage Threshold (TRANSFER – INVERTER)

 

24

 

STANDBY

Adjustment for „Standby“ system

 

 

26

 

INPUT LIMIT

Must be adjusted to the maximal available current of your AC INPUT

 

 

 

 

supply (see on chap. 4.6.3)

 

 

User manual

COMPACT V4.0 E

13

Image 13
Contents Compact V4.0 E User and installer ManualSummary AssemblyGeneral Information IntroductionProgramming Maintenance EC Compliance Technical Data Compact V4.0 EGeneral Information Special Precautions Introduction Principle schematicDescription of main functions Battery connections Place of assembly AssemblyFixing ConnectionProtection cover for the terminals Connections Connecting Plan / Front sideSolar + Pre-installation settings Cabling/wiring Connection to battery Connection the 230Vac-Consumer Device AC OutputConnection to Temperature Sensor Temp Connection to Remote controlConnection the 230Vac Input AC Input Connect the solar modules Solar +/- Only for solar optionDisplay and operating control elements OperatingPush buttons Light Emitting DiodesTurning Knobs Inverter Battery ConditionCharge detection system „Standby OverloadInput current repartition Power sharing Battery chargerCycle of charge Equalization chargingCharging current Transfer systemDelayed mode of the Transfer System Fast UPS- Mode for the Transfer SwitchSolar charge controller option Set the transfer voltage thresholdMultifunctional Contact Remote ControlStandard setting Temperature sensorReset value Battery voltages and absorption timeSet the voltage and timing Threshold Programming the auxiliary contactLED11 PrincipleDisabling some of the Compact functions As per the battery capacityExamples Manual operating of Auxiliary ContactDiagram of the different modes MaintenanceModel Technical Data