2.2.4The solar charge controller (optional)

With the built-in solar charge controller, the COMPACT is a complete solar-power-center. In a solar installation this controller ensures that the batteries are charged correctly. With the COMPACT, batteries can be charged with a generator and with the solar modules at the same time. The charging of batteries with both energy sources is carried out fully automatically.

2.2.5Remote control

As an option, a remote control can be connected to COMPACT. All operating elements and displays with the exception of the level adjustment are available on the remote control. The remote control is furnished with a 20m long cable. This cable can go to 40m long. On the remote control output power and charging current are also shown.

2.3Battery connections

Lead-acid batteries are normally available in blocks of 2V, 6V or 12V. In most cases, to generate the necessary operating voltage and the capacity of the batteries for the COMPACT many batteries have to be connected together in parallel and or in series. Following three examples are shown:

2.3.1Parallel Connection

12V

12V

12V

C 1600-12

2.3.2Series Connection

2V

2V

2V

2V

2V

2V

 

 

 

 

 

C 1600-12

2V

2V

2V

2V

2V

2V

 

 

 

 

 

 

 

 

 

 

 

 

C 2600-24

2V

2V

2V

2V

2V

2V

 

 

 

 

 

 

 

 

 

 

 

 

12V

12V

12V

12V

C 4000-48

 

 

 

 

User manual

COMPACT V4.0 E

7

Image 7
Contents Compact V4.0 E User and installer ManualIntroduction AssemblySummary General InformationProgramming Maintenance EC Compliance Technical Data Compact V4.0 EGeneral Information Special Precautions Introduction Principle schematicDescription of main functions Battery connections Connection AssemblyPlace of assembly FixingProtection cover for the terminals Connections Connecting Plan / Front sideSolar + Connection the 230Vac-Consumer Device AC Output Cabling/wiringPre-installation settings Connection to batteryConnect the solar modules Solar +/- Only for solar option Connection to Remote controlConnection to Temperature Sensor Temp Connection the 230Vac Input AC InputDisplay and operating control elements OperatingPush buttons Light Emitting DiodesTurning Knobs Overload Battery ConditionInverter Charge detection system „StandbyEqualization charging Battery chargerInput current repartition Power sharing Cycle of chargeCharging current Transfer systemSet the transfer voltage threshold Fast UPS- Mode for the Transfer SwitchDelayed mode of the Transfer System Solar charge controller optionMultifunctional Contact Remote ControlBattery voltages and absorption time Temperature sensorStandard setting Reset valuePrinciple Programming the auxiliary contactSet the voltage and timing Threshold LED11Manual operating of Auxiliary Contact As per the battery capacityDisabling some of the Compact functions ExamplesDiagram of the different modes MaintenanceModel Technical Data