Studer Innotec C 1600-12, C 2600-24, C 4000-48 user manual Special Precautions

Page 5

STUDER INNOTEC

COMPACT

During operation of COMPACT, high tensions are generated at the connections and inside of the appliance which could be deadly fatal. Work on the appliance and on the installation should only be carried out by qualified and trained personnel.

The whole installation connected with the COMPACT must comply with the respective valid codes and ordinances.

Persons without the written authorization from Studer INNOTEC are strictly forbidden to carry out any changes or repairs on the appliances. For authorized changes only original parts are to be used.

The COMPACT may only be used when it has been installed in accordance with these instructions and all parts have been correctly assembled and installed.

On the IN- and OUTPUT points of the COMPACT only the already selected energy sources and consumer devices should be connected.

In order to carry out any maintenance or repair work on the COMPACT without danger, all connections must be disconnected beforehand.

Caution: Even when a COMPACT has been disconnected from the all connections, at the OUTPUT point there could still be deadly fatal tensions present. To remove these tensions you must switch on the COMPACT ON with the ON/OFF switch. After one minute the electronics are discharged and any work can now be safely carried out.

The COMPACT is only suitable for internal use and under no circumstances should it be subjected to snow, rain, or any other wet conditions

By installations in motorized vehicles the COMPACT must be protected from water-spray and any other wet conditions.

The COMPACT may only be connected to lead –acid or lead-gel batteries.

Caution: In normal use lead-acid and lead-gel batteries give out explosive gases. Never smoke or allow a spark or flame in the vicinity of batteries. The batteries must always be stored or placed in a well ventilated area, they should be placed in such a way that there is no danger of short circuiting through carelessness. Never charge frozen batteries.

The COMPACT is not to be used or sold for life support equipment or applications.

1.6Special Precautions

While working on batteries there should always be a second person close to you or within your voice range, in case help is needed.

Plenty of fresh water and soap must be ready at hand so that in case of acid coming in contact with skin, eyes and clothes, the areas in question can be thoroughly washed.

If acid enters the eyes, you must thoroughly wash the eyes with cold running water for at least 15 minutes. It is recommended that you immediately consult a medical doctor.

Baking powder neutralizes battery acid electrolyte. Always keep some at hand.

Special care must be taken when working with metal tools near or on the batteries. With tools such as screwdrivers, spanners etc. short-circuits can result. Sparks produced by the short circuit can cause an explosion.

When working on batteries all personal metal items such as rings, necklaces and bracelets must be removed. Batteries are so powerful that short-circuit with these items can melt them and thus cause severe burns. Always follow the battery manufacturer instructions.

Under certain conditions COMPACT or a connected generator can start automatically. While working on an electrical installation you must ensure that these appliances are disconnected beforehand from the installation.

User manual

COMPACT V4.0 E

5

Image 5
Contents Compact V4.0 E User and installer ManualSummary AssemblyGeneral Information IntroductionProgramming Maintenance EC Compliance Technical Data Compact V4.0 EGeneral Information Special Precautions Description of main functions Principle schematicIntroduction Battery connections Place of assembly AssemblyFixing ConnectionSolar + Connecting Plan / Front sideProtection cover for the terminals Connections Pre-installation settings Cabling/wiringConnection to battery Connection the 230Vac-Consumer Device AC OutputConnection to Temperature Sensor Temp Connection to Remote controlConnection the 230Vac Input AC Input Connect the solar modules Solar +/- Only for solar optionDisplay and operating control elements OperatingTurning Knobs Light Emitting DiodesPush buttons Inverter Battery ConditionCharge detection system „Standby OverloadInput current repartition Power sharing Battery chargerCycle of charge Equalization chargingCharging current Transfer systemDelayed mode of the Transfer System Fast UPS- Mode for the Transfer SwitchSolar charge controller option Set the transfer voltage thresholdMultifunctional Contact Remote ControlStandard setting Temperature sensorReset value Battery voltages and absorption timeSet the voltage and timing Threshold Programming the auxiliary contactLED11 PrincipleDisabling some of the Compact functions As per the battery capacityExamples Manual operating of Auxiliary ContactDiagram of the different modes MaintenanceModel Technical Data