Tripp Lite Extended-Run Specifications, Dimensions and Floor Loading, Recommended Torque

Page 15

7 – Specifications

7-1 Dimensions and Floor Loading

 

 

 

 

Dimensions

 

 

 

Battery Cabinet Model

Shelves

 

(Width x Depth x Height)

Weight

Floor Loading

 

BP240V99

3

 

32 x 30 x 58 inches

1760 lb

264 lb/ft2

 

 

(81.3 x 76.2 x 147.3 cm)

(800 kg)

(1292 kg/m2)

 

BP240V120

3

 

32 x 30 x 58 inches

1920 lb

288 lb/ft2

 

 

(81.3 x 76.2 x 147.3 cm)

(873 kg)

(1410 kg/m2)

 

BP240V1207C

3

 

32 x 30 x 58 inches

1983 lb

297 lb/ft2

 

 

(81.3 x 76.2 x 147.3 cm)

(901 kg)

(1452 kg/m2)

 

BP240V150

3

 

32 x 30 x 58 inches

2400 lb

360 lb/ft2

 

 

(81.3 x 76.2 x 147.3 cm)

(1091 kg)

(1762 kg/m2)

 

BP240V1507C

3

 

32 x 30 x 58 inches

2463 lb

369 lb/ft2

 

 

(81.3 x 76.2 x 147.3 cm)

(1120 kg)

(1804 kg/m2)

 

BP480V55

3

 

32 x 30 x 58 inches

2050 lb

308 lb/ft2

 

 

(81.3 x 76.2 x 147.3 cm)

(932 kg)

(1505 kg/m2)

 

BP480V78

4

 

40.25 x 30.25 x 79 inches

2960 lb

350 lb/ft2

 

 

(102.2 x 76.8 x 200.7 cm)

(1345 kg)

(1714 kg/m2)

 

BP480V103

4

 

40.25 x 30.25 x 79 inches

3650 lb

432 lb/ft2

 

 

(102.2 x 76.8 x 200.7 cm)

(1659 kg)

(2114 kg/m2)

 

BP480V140

4

 

40.25 x 30.25 x 79 inches

4625 lb

547 lb/ft2

 

 

(102.2 x 76.8 x 200.7 cm)

(2102 kg)

(2678 kg/m2)

 

BP348V55

4

 

40.25 x 30.25 x 79 inches

2284 lb

271 lb/ft2

 

 

(102.2 x 76.8 x 200.7 cm)

(1038 kg)

(1322 kg/m2)

 

BP348V78

4

 

40.25 x 30.25 x 79 inches

2545 lb

301 lb/ft2

 

 

(102.2 x 76.8 x 200.7 cm)

(1157 kg)

(1474 kg/m2)

 

BP348V103

4

 

40.25 x 30.25 x 79 inches

2783 lb

330 lb/ft2

 

 

(102.2 x 76.8 x 200.7 cm)

(1265 kg)

(1612 kg/m2)

 

BP348V150

4

 

40.25 x 30.25 x 79 inches

3489 lb

413 lb/ft2

 

 

(102.2 x 76.8 x 200.7 cm)

(1586 kg)

(2021 kg/m2)

7-2 Recommended Torque

 

Battery Cabinet Model

 

 

Individual Battery

 

 

Terminal Type

 

 

Torque

 

 

 

 

 

 

 

 

 

 

 

 

Unit Model

 

 

 

 

 

 

BP240V99

 

UPS12-350MR

 

1/4-20 Threaded Insert

 

110 in·lb (12.4 N·m)

 

 

 

 

 

 

 

 

 

BP240V120

 

UPS12-400MR

 

1/4-20 Threaded Insert

 

110 in·lb (12.4 N·m)

 

 

 

 

 

 

 

 

 

BP240V1207C

 

UPS12-400MR

 

1/4-20 Threaded Insert

 

110 in·lb (12.4 N·m)

 

 

 

 

 

 

 

 

 

BP240V150

 

UPS12-490MR

 

1/4-20 Threaded Insert

 

110 in·lb (12.4 N·m)

 

 

 

 

 

 

 

 

 

BP240V1507C

 

UPS12-490MR

 

1/4-20 Threaded Insert

 

110 in·lb (12.4 N·m)

 

 

 

 

 

 

 

 

 

BP480V55

 

UPS12-210MR

 

10-32 Threaded Insert

 

25 in·lb (2.8 N·m)

 

 

 

 

 

 

 

 

 

BP480V78

 

UPS12-300MR

 

1/4-20 Threaded Insert

 

110 in·lb (12.4 N·m)

 

 

 

 

 

 

 

 

 

BP480V103

 

UPS12-400MR

 

1/4-20 Threaded Insert

 

110 in·lb (12.4 N·m)

 

 

 

 

 

 

 

 

 

BP480V140

 

UPS12-490MR

 

1/4-20 Threaded Insert

 

110 in·lb (12.4 N·m)

 

 

 

 

 

 

 

 

 

BP348V55

 

UPS12-210MR

 

10-32 Threaded Insert

 

25 in·lb (2.8 N·m)

 

 

 

 

 

 

 

 

 

BP348V78

 

UPS12-300MR

 

1/4-20 Threaded Insert

 

110 in·lb (12.4 N·m)

 

 

 

 

 

 

 

 

 

BP348V103

 

UPS12-400MR

 

1/4-20 Threaded Insert

 

110 in·lb (12.4 N·m)

 

 

 

 

 

 

 

 

 

BP348V150

 

UPS12-490MR

 

1/4-20 Threaded Insert

 

110 in·lb (12.4 N·m)

 

 

 

 

 

 

 

 

 

 

 

 

[15]

Image 15
Contents Extended-Run 3-Phase Battery Cabinet Introduction FeaturesImportant Safety Instructions Installation and Location WarningsConnection Warnings Battery Warnings Mechanical Check Battery Cabinet InstallationPreparation TransportationInternal Wiring Typical Battery Cabinet PlacementPreliminary Electrical Check Battery Charger Electrical Connection Select Models Electrical ConnectionFinal Electrical Check Operational Check Operation and ChargingDetermine Charging Voltages Initial ChargeMaintenance Maintenance ScheduleFuse Replacement Battery Cabinet Diagram 4 Shelves DiagramsBattery Cabinet Diagram 3 Shelves Battery and Breaker Diagrams 240 VDC Battery and Breaker Diagrams +/- 240 VDC 4 & 5Warning Do not connect the battery charger Integrated Battery Charger Select ModelsSpecifications Dimensions and Floor LoadingRecommended Torque Warranty Storage and Service