Feature Identification
Identify the premium features on your specific model and quickly locate instructions on how to maximize their use.
1 Configuration DIP Switches: optimize Inverter/Charger operation depending on your application. See page 6 for setting instructions.
2Operating Mode Switch: controls Inverter/Charger operation. The “AUTO/REMOTE” setting ensures your equipment receives constant, uninterrupted AC power. It also enables the Inverter/Charger to be remotely monitored and controlled with an optional remote module (Tripp Lite model APSRM2, sold separately). The “CHARGE ONLY” setting allows your batteries to return to full charge faster by turning the inverter off which halts battery discharging. See page 5 for setting instructions.
3Operation Indicator Lights: intuitive “traffic light” signals show whether the Inverter/Charger is operating from AC line power or DC battery power. It also warns you if the connected equipment load is too high. See page 5 for instructions on reading indicator lights.
4Battery Indicator Lights: intuitive “traffic light” signals show approximate charge level of your battery. See page 5 for instructions on reading indicator lights.
5DC Power Terminals: connect to your battery terminals. See page 9 for connection instructions.
6AC Output Receptacles: allow you to connect equipment that would normally be plugged into a utility outlet. A universal adapter, included, allows you to connect a wide variety of plug styles to the NEMA receptacle. See page 10 for connection instructions.
7AC Input Receptacle: connects the Inverter/Charger to any source of utility- or
8Resettable Circuit Breakers: protect your Inverter/Charger against damage due to overload. See page 5 for resetting instructions.
9Remote Control Module Connector: allows remote monitoring and control with an optional module (Tripp Lite model APSRM2, sold separately). See remote module owner’s manual for connection instructions.
10Main Ground Lug: properly grounds the Inverter/Charger to earth ground or to vehicle or boat grounding system. See page 9 for connection instructions.
11
11 | 1 | 4 | 9 | 3 | 2 | 8 |
Front View (APSINT612)
5 |
| 7 |
| 10 |
| 6 |
4A