Tripp Lite BP Series owner manual Important Safety Instructions

Page 2

Important Safety Instructions

SAVE THESE INSTRUCTIONS

This manual contains instructions and warnings that should be followed during the installation, operation and storage of this product. Failure to heed these warnings will void your warranty and may lead to equipment damage, personal injury or death.

WARNING!

The included mounting shelves are not intended to support more than one battery pack. Do not attempt to stack multiple battery packs on a single set of mounting shelves. Do not attempt to install the battery pack in a 2-post rack. Failure to follow these warnings will create a risk of equipment damage and personal injury.

DANGER! LETHAL HIGH VOLTAGE HAZARD!

Potentially lethal high voltage exists within the battery pack, even when it is not connected to a UPS system. Internal battery removal/replacement should be performed by qualified electricians or service personnel only, following all the precautions listed in this manual and adhering to local electrical codes.

Location Warnings

Install the battery pack indoors, away from excess moisture, humidity, temperature extremes, conductive contaminants, dust and direct sunlight.

For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C).

Leave adequate space around all sides of the battery pack for proper ventilation.

Installation Warnings

Use caution when attempting to move or lift the battery pack. Because of the weight of the battery pack, two or more people should assist each other in lifting and installing it.

The weight of the 4U external battery pack requires the internal batteries to be removed before installing the battery pack in a 4-post rack or rack enclosure. Read all installation instructions and warnings fully before proceeding with installation.

The 4U battery pack is too heavy for 2-post rack installation. Do not attempt to install the 4U battery pack in a 2-post rack.

The 4U battery pack should be mounted as low in the rack or rack enclosure as possible.

Do not attempt to stack the 4U battery pack on top of the UPS power module.

Suggested installation procedures apply to mounting the battery pack in common rack and rack enclosure types and may not be appropriate for all rack configurations. The installer must determine the fitness of hardware and procedures before installation.

UPS Connection Warnings

Confirm that the battery pack and UPS system use the same DC voltage before connecting them together.

Do not attempt to modify the battery connectors or cables, and do not attempt to use adapters of any kind.

Do not connect or disconnect an external battery pack while the UPS system is operating on battery power, due to the possibility of dangerous arcing.

When connecting multiple battery packs to a single UPS system, the battery packs should be approximately the same age, with the same level of wear.

Small sparks may be produced when connecting or disconnecting external battery packs. This is normal.

Always use the connector retention brackets to secure the battery pack connection. Do not attempt to operate the UPS system without the connector retention brackets.

Equipment Connection Warnings

Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.

Battery Warnings

The battery pack does not require routine maintenance. There are no user-serviceable parts inside.

Due to the risk of injury from contact with potentially lethal high voltage, battery removal/replacement must be performed by qualified electricians or service personnel.

Observe proper precautions during battery removal/replacement. Unplug the battery pack from the UPS system before removing/replacing batteries. Do not short or bridge battery terminals with any object. Use tools with insulated handles. Remove metal objects such as watches and rings before working with batteries. Do not open batteries or remove plastic battery sleeves. Replace batteries only with sealed lead-acid batteries of the same number, type, voltage and amp-hour capacity.

The batteries are recyclable. Do not dispose of the batteries in a fire. Refer to local codes for disposal requirements, or in the USA only, refer to these sources for recycling information: 800-SAV-LEAD (800-728-5323), 800-8-BATTERY (800-822-8837) or www.rbrc.com.

2

Image 2
Contents BP Series 4U External Battery Pack Important Safety Instructions Post Rack Mounting Additional Battery Pack Connection Daisy-Chaining Internal Battery InsertionUPS Power Module Connection Service MaintenanceTroubleshooting StorageManual del Propietario Instrucciones de Seguridad Importantes Remoción de la Batería Interna Montaje en bastidor de 4 PostesConexión del Módulo de Potencia del UPS Instalación en Bastidor continúaInserción de la Batería Interna Mantenimiento Solución de ProblemasAlmacenje y Servicio AlmacenajeNota Sobre las Etiquetas Manuel du propriétaire Importantes consignes de sécurité Montage en bâti à 4 montants Connexion au module dalimentation de londuleur Installation en bâti suiteInsertion de la batterie interne Connexion de bloc-batteries supplémentaires SérieEntreposage EntretienDépannage Réparations

BP Series specifications

Tripp Lite, a trusted name in power protection and connectivity solutions, offers the BP Series of uninterruptible power supplies (UPS) designed to provide reliable power protection for various electronic devices. These UPS systems are particularly beneficial for small to medium-sized businesses, home offices, and critical home electronics.

One of the main features of the BP Series is its innovative line-interactive technology. This technology allows the UPS to automatically regulate voltage fluctuations, ensuring that connected equipment receives consistent power. It can provide battery backup during power outages, giving users the peace of mind that their devices will remain operational during critical moments.

Another standout characteristic of the BP Series is its smart battery management system. This system utilizes advanced techniques for battery charging and discharging, promoting longer battery life and optimizing performance. Users will find that the BP Series supports hot-swappable batteries, which allows for easy replacement without the need to power down connected devices.

The BP Series is designed with multiple outlets, providing versatility to accommodate various devices. With universal NEMA outlets available, users can connect computers, networking equipment, and other electronics without needing special adapters. Additionally, some models in the series include USB charging ports, enhancing convenience for charging smartphones and tablets directly from the UPS.

In terms of monitoring and management, Tripp Lite's BP Series offers a series of LED indicators that provide real-time status updates, making it easy for users to assess the health and performance of their UPS at a glance. More advanced models in the series may come equipped with USB ports and compatible software for detailed monitoring and control options through a computer interface.

The BP Series is built with durable, high-quality engineering, ensuring that it can withstand everyday use while providing reliable service. Safety features such as surge protection and short-circuit protection are integral to the design, shielding connected devices from power surges, spikes, and other electrical anomalies.

Overall, Tripp Lite's BP Series combines robust performance, essential features, and user-friendly design to deliver dependable power protection, making it an excellent choice for anyone seeking to safeguard electronics against power disturbances. Whether it's for personal or professional use, this series offers admirable value and performance tailored to a range of power needs.