Sony MDS-NT1 Section Test Mode, Precautions for USE of Test Mode, Setting the Test Mode

Page 20

MDS-NT1

SECTION 4

TEST MODE

Note 1:The test mode and recording of this set are controlled by a personal computer, thus requiring the set to be connected to the PC. Prepare the personal computer in which necessary software is already installed.

Attached software “OpenMG Jukebox” (necessary for recording (check in, check out)) (Part No. : 4-237-880-01)

Software for test mode “TestMode_S.exe” (“TestMode_S.exe” and essential files “data_files.csv”, “Net MDUSB.dil” are distributed to- gether with the Service Manual. For the test mode, copy these three files in the same folder beforehand)

Note 2:In the operation in the test mode, the operational description requiring “click [xxx]” means that you have to click the button on the screen. (“xxx” indicates the button name)

Note 3: MD always plays double speed.

4-1. PRECAUTIONS FOR USE OF TEST MODE

The software for test mode is used.

Be sure to start the software for test mode after quitting the application software.

As loading related operations will be performed regardless of the test mode operations being performed, be sure to check that the disc is stopped before setting and removing it.

Even if the [EJECT] is clicked while the disc is rotating during continuous playback, continuous recording, etc., the disc will not stop rotating.

Therefore, it will be ejected while rotating.

Be sure to click the [EJECT] button after clicking the [MENU/NO] and the rotation of disc is stopped.

4-1-1. Recording laser emission mode

Continuous recording mode (CREC MODE)

Laser power check mode (LDPWR CHECK)

Laser power adjustment mode (LDPWR ADJUST)

Iop check (Iop compare)

Iop value non-volatile writing (Iop NV save)

Traverse (MO) check (EF MO CHECK)

Traverse (MO) adjustment (EF MO ADJUST)

4-2. SETTING THE TEST MODE

1.Press the [B/>] button and [x/Z] button until the NetMD indicator turns off (for more than 3 seconds). (During this step, the USB cable must be disconnected)

2.Connect the set to the PC with the attached USB cable.

3.Start up the software for test mode.

4.Click the [TEST MODE].

5.When the test mode is set, “[Check]” will be displayed. Click the [JOG UP] or [JOG UP] switches between the following three groups; ···Tt [Check] Tt [Service] Tt [Develop] Tt ···.

Note: Do not use the test mode in the [Develop] group.

If used, the unit may not operate normally.

If the [Develop] group is set accidentally, click the [MENU/NO] immediately to exit the [Develop] group.

4-3. RELEASING THE TEST MODE

Quit the software for test mode after [REPEAT] is clicked.

Note: When retrying test mode setting, perform the setting method from the start once again.

4-4. BASIC OPERATIONS OF THE TEST MODE

All operations are performed clicking the [JOG UP], [JOG DOWN], [PUSH], [ENTER/YES], and [MENU/NO]. The functions of these buttons are as follows.

Function name

Function

 

 

[JOG UP], [JOG DOWN]

Select

 

 

[PUSH]

Set Sub menu

 

 

[ENTER/YES]

Proceeds onto the next step. Finalizes input

 

 

[MENU/NO]

Returns to previous step. Stops operations

 

 

20

Image 20
Contents Specifications MDS-NT1Playback Recording Cause/Remedy Indicator Green Red MDS-NT1 SELF-DIAGNOSIS FunctionItems of Error History Mode Items and Contents MDS-NT1Table of Error Codes Error Code Details of ErrorTable of Contents DisassemblyDiagrams SELF-DIAGNOSIS FunctionFlexible Circuit Board Repairing MDS-NT1 Section Servicing Notes BD Board Conductor SideJIG for Checking BD Board Waveform Record Procedure Checks Prior to Parts Replacement and Adjustments in MD Criteria for Determination Measure if unsatisfactoryService Mode Software ResetMicrocomputer Version Display System RequirementsMDS-NT1 Section General Front ViewMDS-NT1 Section Disassembly Disassembly FlowCase Upper Main Board MD Mechanism Deck MDM-7S2BFront Panel Section BD BOARD, Over Write Head HR901Holder Assy Loading Motor Assy M103Sled Motor Assy M102 Optical PICK-UP KMS-262ESpindle Motor Assy M101 MDS-NT1 Section Test Mode Precautions for USE of Test ModeSetting the Test Mode Releasing the Test ModeSelecting the Test Mode CheckOperating the Continuous Playback Mode Automatic SELF-DIAGNOSIS Function InformationCheck before replacement MDS-NT1 Section Electrical AdjustmentsParts Replacement and Adjustment Adjustment flow YESPrecautions for Checking Laser Diode Emission Precautions for USE of Optical PICK- UP KMS-262A/262EHOW to Identify Optical PICK-UP KMS- 262A/KMS-262E KMS-262A KMS-262EPrecautions for Adjustments Laser power meterUsing the Continuously Recorded Disc Temperature Compensation Offset CheckLaser Power Check Checks Prior to RepairsTraverse Check Auto CheckOther Checks Play Check MO Error Rate Check CD Error Rate CheckFocus Bias Check Self-Recording/playback CheckInitial Setting of Adjustment Value Temperature Compensation Offset AdjustmentLaser Power Adjustment Recording and Displaying the IopTraverse Adjustment Iop NV SaveFocus Bias Adjustment ENTER/YES buttonError Rate Check Auto Gain Control Output Level AdjustmentCD Auto Gain Control Output Level Adjustment MO Auto Gain Control Output Level AdjustmentAdjustment and Checking Loacation MDS-NT1 Section Diagrams Block Diagram Servo SectionBlock Diagram Main Section 36 aWaveforms BD Board 22.7 nsPrinted Wiring Board BD Board Semiconductor Location4AA 3AA Schematic Diagram BD Board 2/2 See page 38 for Waveforms B3B 2BBPrinted Wiring Board Main Board Component Side IC451Printed Wiring Board Main Board Conductor Side Main Board1AA AA2 AA3 GND Printed Wiring Board Panel Board Panel Board Conductor SideSchematic Diagram Panel Board IC Block Diagrams BD Board CXA2523ARIC401 BH6519FS-E2 Main BoardIC440 M54641L BD Board IC101 CXA2523AR RF AMP, FOCUS/TRACKING Error AMP IC PIN Function DescriptionMNT2 Xbusy Xcas APC Main Board IC301 M30835FJGP-01 System Controller PLAY-SW Pin No Extal Section MDS-NT1 Exploded Views Case Section56 4-951-620-01 Screw 2.6X8, +BVTP 104 105 Case B Section102 101 103 317 303 307 311 310 319 304 308302 306 320 301 305 313 314 315 316 359 358 357 360 356364 355 354 362 359 352MDS-NT1 Section Electrical Parts List ResistorsDiode Switch MDS-NT1 MainFB1 MDS-NT1 Main Panel MiscellaneousMotor ASSY, Loading Revision History