MDS-NT1
5-6. USING THE CONTINUOUSLY RECORDED DISC
*This disc is used in focus bias adjustment and error rate check. The following describes how to create a continuous recording disc.
1.Insert a disc (blank disc) commercially available.
2.Check the [JOG UP] or [JOG DOWN] and display “CREC 2MODE” (C37).
3.Click the [ENTER/YES] again to display “CREC 2MID”. Display “CREC 2 (0300)” and start to recording.
4.Complete recording within 5 minutes.
5.Click the [MENU/NO] and stop recording .
6.Click the [EJECT] and remove the disc.
The above has been how to create a continuous recorded data for the focus bias adjustment and error rate check.
Note: Be careful not to apply vibration during continuous recording.
5-7. CHECKS PRIOR TO REPAIRS
These checks are performed before replacing parts according to “approximate specifications” to determine the faulty locations. For details, refer to “Checks Prior to Parts Replacement and Adjust- ments” (see page 10).
5-7-1. Temperature Compensation Offset Check
When performing adjustments, set the internal temperature and room temperature to 22 to 28ºC.
Checking Procedure:
1.Click the [JOG UP] or [JOG DOWN] to display “TEMP CHECK” (C12).
2.Click the [ENTER/YES].
3.“T=@@(##) [OK” should be displayed. If “T=@@ (##) [NG” is displayed, it means that the results are bad.
(@@ indicates the current value set, and ## indicates the value written in the
5-7-2. Laser Power Check
Before checking, check the Iop value of the optical
Connection:
laser
power meter
Optical
digital voltmeter
BD board |
|
|
CN105 pin 1 (I +3 V) | + | |
CN105 pin 2 | (Iop) | – |
Checking Procedure:
1.Set the laser power meter on the objective lens of the optical
Connect the digital volt meter to CN105 pin 1 (I+3V) and CN105 pin 2 (Iop).
2.Then, click the [JOG UP] or [JOG DOWN] and display “LDPWR CHECK” (C13).
3.Click the [ENTER/YES] once and display “L 0.90 mW $ ”. Check that the reading of the laser power meter become speci- fied value.
Specified Value:
Laser power meter reading : 0.84 to 0.92 mW
0.90to 0.96 mW
4.Click the [ENTER/YES] once more and display “L 8.40 mW $
”
Specified Value:
Laser power meter reading : 8.4 ± 0.3 mW
8.65± 0.25 mW
Digital voltmeter reading : Optical
(Optical pick-up label)
KMS262A | (For details of the method for | |
20101 | checking this value, refer to | |
Recording and Displaying the Iop | ||
B0825 | ||
Information”) | ||
| ||
|
Iop = 82.5 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (Ω )
5.Click the [MENU/NO] and display “LDPWR CHECK” (C13) and stop the laser emission.
(The [MENU/NO] is effective at all times to stop the laser emis- sion)
Note: After step 4, each time the [ENTER/YES] is clicked, the display will be switched between “L 0.70 mW $ ” and “L 7.50 mW $ ”, Nothing needs to be performed here.
Checking Location: BD board (see page 35)
5-7-3. Iop Compare
The current Iop value at laser power 8.4 mW output and reference Iop value (set at shipment) written in the nonvolatile memory are compared, and the rate of increase/decrease will be displayed in percentage.
Note: Perform this function with the optical
Procedure:
1.Click the [JOG UP] or [JOGDOWN] to display “Iop Compare” (C27).
2.Click the [ENTER/YES] and start measurements.
3.When measurements complete, the display changes to “± xx%yy”.
xx is the percentage of increase/decrease, and OK or NG is displayed at yy to indicate whether the percentage of increase/ decrease is within the allowable range.
4.Click the [MENU/NO] to end this mode.
28