5-15. ERROR RATE CHECK
5-15-1. CD Error Rate Check
Checking Procedure:
1.Load the check disc (MD)
2.Click the [JOG UP] or [JOG DOWN] to display “CPLAY2 MODE” (C36).
3.Click the [ENTER/YES] twice and display “CPLAY2MID”.
4.The display changes to “C = AD = ”.
5.Check that the C1 error rate is below 20.
6.Click the [MENU/NO] to stop playback, then click the [EJECT] and take out the check disc.
Checking Procedure:
1.Load the
2.Click the [JOG UP] or [JOG DOWN] to display “CPLAY2 MODE” (C36).
3.Click the [ENTER/YES] to display “CPLAY2MID”.
4.The display changes to “C = AD = ”.
5.If the C1 error rate is below 20, check that ADER is 00.
6.Click the [MENU/NO] to stop playback, then click the [EJECT] and take out the test disc.
5-16. FOCUS BIAS CHECK
Change the focus bias and check the focus tolerance amount.
Checking Procedure:
1.Load the
2.Click the [JOG UP] or [JOG DOWN] to display “CPLAY2 MODE” (C36).
3.Click the [ENTER/YES] twice to display “CPLAY2MID”.
4.Click the [MENU/NO] when “C = AD = ” is displayed.
5.Click the [JOG UP] or [JOG DOWN] to display “FBIAS CHECK” (C16).
6.Click the [ENTER/YES] to display “ / c = ”.
The first four digits indicate the C1 error rate, the two digits after “/ ” indicate ADER, and the 2 digits after “c =” indicate the focus bias value.
Check that the C1 error is below 20 and ADER is below 2.
7.Click the [ENTER/YES] and display “ / b = ”. Check that the C1 error is about 100 and ADER is below 2.
8.Click the [ENTER/YES] and display “ / a = ”. Check that the C1 error is about 100 and ADER is below 2
9.Click the [MENU/NO], then click the [EJECT] and take out the disc.
Note: If the C1 error and ADER are above other than the specified value at points a (step 8. in the above) or b (step 7. in the above), the focus bias adjustment may not have been carried out prop- erly. Adjust perform the beginning again.
5-17. AUTO GAIN CONTROL OUTPUT LEVEL ADJUSTMENT
Be sure to perform this adjustment when the optical
If the adjustment results becomes “Adjust NG!”, the optical pick- up may be faulty or the servo system circuits may be abnormal.
5-17-1. CD Auto Gain Control Output Level Adjustment
Adjusting Procedure:
1.Load the check disc (MD)
2.Click the [JOG UP] or [JOG DOWN] to display “AG Set (CD)” (C11).
3.When the [ENTER/YES] is clicked, the adjustment will be performed automatically.
“Complete!!” will then be displayed momentarily when the value is recorded in the
4.Click the [EJECT] and take out the check disc.
5-17-2. MO Auto Gain Control Output Level Adjustment
Adjusting Procedure:
1.Load the test disc
2.Click the [JOG UP] or [JOG DOWN] to display “AG Set (MO)” (C10).
3.When the [ENTER/YES] is clicked, the adjustment will be performed automatically.
“Complete!!” will then be displayed momentarily when the value is recorded in the
4.Click the [EJECT] and take out the test disc.
34