Sony MDS-NT1 service manual Selecting the Test Mode, Check

Page 21

MDS-NT1

4-5. SELECTING THE TEST MODE

There are 26 types of test modes as shown below. The groups can be switched by clicking the [JOG UP] or [JOG DOWN]. After selecting the group to be used, click the [ENTER/YES]. After setting a certain group, click the [JOG UP] or [JOG DOWN] switches between these modes.

Refer to “Group” in the table for details can be selected.

All items used for servicing can be treated using group [Service]. So be carefully not to enter other groups by mistake.

Note: Do not use the test mode in the [Develop] group.

If used, the unit may not operate normally.

If the [Develop] group is set accidentally, click the [MENU/NO] immediately to exit the [Develop] group.

Display

No.

Details

Mark

Group

Service

 

 

 

Check

AUTO CHECK

C01

Automatic self-diagnosis

 

 

Err Display

C02

Error history display, clear

 

 

TEMP ADJUST

C03

Temperature compensation offset adjustment

 

 

LDPWR ADJUST

C04

Laser power adjustment

 

 

Iop Write

C05

Iop data writing

 

 

Iop NV Save

C06

Writes current Iop value in read nonvolatile memory using microprocessor

 

 

EF MO ADJUST

C07

Traverse (MO) adjustment

 

 

EF CD ADJUST

C08

Traverse (CD) adjustment

 

 

FBIAS ADJUST

C09

Focus bias adjustment

 

 

AG Set (MO)

C10

Auto gain output level adjustment (MO)

 

 

AG Set (CD)

C11

Auto gain output level adjustment (CD)

 

 

TEMP CHECK

C12

Temperature compensation offset check

 

 

LDPWR CHECK

C13

Laser power check

 

 

EF MO CHECK

C14

Traverse (MO) check

 

 

EF CD CHECK

C15

Traverse (CD) check

 

 

FBIAS CHECK

C16

Focus bias check

 

 

ScurveCHECK

C17

S-curve check

 

 

VERIFYMODE

C18

Nonvolatile memory check

 

 

DETRK CHECK

C19

Detrack check

 

 

0920 CHECK

C25

Most circumference check

 

 

Iop Read

C26

Iop data display

 

 

Iop Compare

C27

Comparison with initial Iop value written in nonvolatile memory

 

 

ADJ CLEAR

C28

Initialization of nonvolatile memory for adjustment values

 

 

INFORMATION

C31

Display of microprocessor version, etc.

 

 

CPLAY2MODE

C36

Continuous playback mode

 

 

CREC 2MODE

C37

Continuous recording mode

 

 

For details of each adjustment mode, refer to “SECTION 5. Electrical Adjustments”. For details of “Err Display”, refer to “Self-Diagnosis Function” on page 2.

If a different mode has been selected by mistake, click the [MENU/NO] to release that mode.

Modes with () in the Mark column are not used for servicing and therefore are not described in detail. If these modes are set acciden- tally, click the [MENU/NO] to release the mode immediately.

21

Image 21
Contents MDS-NT1 SpecificationsMDS-NT1 SELF-DIAGNOSIS Function Playback Recording Cause/Remedy Indicator Green RedMDS-NT1 Items of Error History Mode Items and ContentsError Code Details of Error Table of Error CodesDisassembly Table of ContentsDiagrams SELF-DIAGNOSIS FunctionFlexible Circuit Board Repairing BD Board Conductor Side MDS-NT1 Section Servicing NotesJIG for Checking BD Board Waveform Record Procedure Criteria for Determination Measure if unsatisfactory Checks Prior to Parts Replacement and Adjustments in MDSoftware Reset Service ModeMicrocomputer Version Display System RequirementsFront View MDS-NT1 Section GeneralDisassembly Flow MDS-NT1 Section DisassemblyCase Upper MD Mechanism Deck MDM-7S2B Main BoardBD BOARD, Over Write Head HR901 Front Panel SectionLoading Motor Assy M103 Holder AssyOptical PICK-UP KMS-262E Sled Motor Assy M102Spindle Motor Assy M101 Precautions for USE of Test Mode MDS-NT1 Section Test ModeSetting the Test Mode Releasing the Test ModeCheck Selecting the Test ModeOperating the Continuous Playback Mode Information Automatic SELF-DIAGNOSIS FunctionMDS-NT1 Section Electrical Adjustments Parts Replacement and AdjustmentCheck before replacement YES Adjustment flowPrecautions for USE of Optical PICK- UP KMS-262A/262E Precautions for Checking Laser Diode EmissionHOW to Identify Optical PICK-UP KMS- 262A/KMS-262E KMS-262A KMS-262ELaser power meter Precautions for AdjustmentsTemperature Compensation Offset Check Using the Continuously Recorded DiscLaser Power Check Checks Prior to RepairsAuto Check Other ChecksTraverse Check CD Error Rate Check Play Check MO Error Rate CheckFocus Bias Check Self-Recording/playback CheckTemperature Compensation Offset Adjustment Initial Setting of Adjustment ValueLaser Power Adjustment Recording and Displaying the IopIop NV Save Traverse AdjustmentENTER/YES button Focus Bias AdjustmentAuto Gain Control Output Level Adjustment Error Rate CheckCD Auto Gain Control Output Level Adjustment MO Auto Gain Control Output Level AdjustmentAdjustment and Checking Loacation Block Diagram Servo Section MDS-NT1 Section Diagrams36 a Block Diagram Main Section22.7 ns Waveforms BD BoardSemiconductor Location Printed Wiring Board BD Board4AA 3AA B3B 2BB Schematic Diagram BD Board 2/2 See page 38 for WaveformsIC451 Printed Wiring Board Main Board Component SideMain Board Printed Wiring Board Main Board Conductor Side1AA AA2 AA3 GND Panel Board Conductor Side Printed Wiring Board Panel BoardSchematic Diagram Panel Board CXA2523AR IC Block Diagrams BD BoardMain Board IC401 BH6519FS-E2IC440 M54641L IC PIN Function Description BD Board IC101 CXA2523AR RF AMP, FOCUS/TRACKING Error AMPMNT2 Xbusy Xcas APC Main Board IC301 M30835FJGP-01 System Controller PLAY-SW Pin No Extal Case Section Section MDS-NT1 Exploded Views56 4-951-620-01 Screw 2.6X8, +BVTP Case B Section 102 101 103104 105 311 310 319 304 308 302 306 320 301 305 313 314 315 316317 303 307 358 357 360 356 359364 355 354 362 359 352Resistors MDS-NT1 Section Electrical Parts ListDiode MDS-NT1 Main SwitchFB1 Miscellaneous MDS-NT1 Main PanelMotor ASSY, Loading Revision History