OPERATION INSTRUCTIONS

Start-Up

Read all safety warnings before performing operation. Do not attempt to operate this air compressor until you have read and understood all safety precautions and instructions listed in this manual.

1.Flip the toggle on top of the pilot valve to the upright position. This provides a loadless start. The air compressor will unload and allow easier engine start- up.

2.Start the engine. Refer to the Engine Manual.

3.When the engine has run for 1-2 minutes, flip toggle back to the original position.

4.Set pressure by adjusting the pressure regulator counterclockwise for less pressure and clockwise for more pressure.

Notice

If you notice any unusual noise or vibration, stop the air compressor and refer to “Troubleshooting”.

Shutdown

1.To stop the air compressor, move the engine switch to the “OFF” position. Refer to the Engine Manual.

2.Drain air from the air tanks by releasing air with an attached air tool or by pulling on the safety relief valve.

3.Once the air tank pressure gauge registers under 10 pounds, open the drain valve under each air tank to drain any moisture.

4.Allow the air compressor to cool down.

5.Wipe air compressor clean and store in a safe, non- freezing area.

11

Image 11
Contents Pressure AirMax Gas Air CompressorContents Burst Hazard Toxic Fumes Hazard Personal Protective Equipment Component Identification Model 1310G Component Identification Initial Setup Installation & Preparation InstructionsGasoline Engine Pre-Start ChecklistShutdown Start-UpMaintenance Instructions Problem Cause Solution TroubleshootingTroubleshooting Page Model 1310G Description QTY 16E739 for use with Model 1310G Pump Assembly Parts Model 1720G Air Compressor Parts 16E738 for use with Model 1720G KIT, REPAIR, Valve Plate Assy Page Technical Data Graco Information For Graco Canada Customers