Graco 3A0595D important safety instructions Maintenance Instructions

Page 12

MAINTENANCE INSTRUCTIONS

Read the instruction manual before performing main- tenance. The following procedures must be performed when stopping the air compressor for maintenance or service.

1.Turn off air compressor.

2.Disconnect spark plug wire from engine.

3.Open all drains.

4.Wait for the air compressor to cool before starting service.

Interval

What to do

 

 

Daily

Check pump oil level. Check engine oil

 

level. Oil leak inspection. Check engine

 

air filter. Drain condensation in air

 

tank(s). Inspect guards/covers. Check

 

unusual noise/vibration. Check for air

 

leaks.

 

 

Weekly

Clean exterior of compressor. Inspect

 

air filter.

 

 

Monthly

Inspect belt. Check safety relief valve.

 

 

200 hours

Change pump oil*. Replace air filter.

 

Check engine spark plug.

 

 

Notice

*The pump oil must be changed after the first 50 hours of operation and every 200 hours or 3 months, whichever comes first.

The engine oil must be changed after the first 8 hours of operation and every 50 hours or 3 months, whichever comes first.

Every 2 years, an Authorized Service Technician should check the check valve, intake valves and delivery valves.

12

Image 12
Contents AirMax Gas Air Compressor PressureContents Burst Hazard Toxic Fumes Hazard Personal Protective Equipment Component Identification Model 1310G Component Identification Installation & Preparation Instructions Initial SetupPre-Start Checklist Gasoline EngineStart-Up ShutdownMaintenance Instructions Troubleshooting Problem Cause SolutionTroubleshooting Page Model 1310G Description QTY 16E739 for use with Model 1310G Pump Assembly Parts Model 1720G Air Compressor Parts 16E738 for use with Model 1720G KIT, REPAIR, Valve Plate Assy Page Technical Data For Graco Canada Customers Graco Information