Graco 262893 important safety instructions Operation, Pressure Relief Procedure

Page 10

Operation

Operation

Pressure Relief Procedure

6. Disengage trigger lock.

Follow the Pressure Relief Procedure whenever you see this symbol.

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing the equipment.

ti19265a1

7.Hold a metal part of the gun firmly to a grounded metal pail with a splash guard in place. Trigger gun to relieve pressure in material hoses.

Relieve A and B Fluid Pressure

1. Engage trigger lock.

ti19265a1

2.Press Stop to turn sprayer OFF.

3.Close all air motor supply valves or any source of fluid pressure.

4.If fluid heaters are used, shut them off using the controls on the display module.

5.Shut off RAM air supply.

ti19269a

8.Engage trigger lock.

9.Close the mix manifold inlet ball valves (C, D).

10.Flush mixed material hoses, mixer, and gun. See Flush on page 11.

10

3A2988B

Image 10
Contents XM PFP Mix Manifold Contents Related ManualsSkin Injection Hazard Equipment Misuse Hazard Keep Components a and B Separate Changing MaterialsComponent Identification T2* UOverview Top ViewInstallation Flush Before Using Equipment GroundingPressure Relief Procedure OperationFlush Dispensing and Spraying Volume Balancing the Mix Manifold Lead/Lag ImbalanceReference Formula Clean Static Mixers MaintenanceClean Mix Manifold Outlet Troubleshooting Clean Mix Manifold Outlet,Repair Check ValvesParts Mix ManifoldMix Manifold Parts Technical Data Graco Standard Warranty Graco Information