Technical Data

Maximum working pressure . . . 6000 psi (41 MPa, 414 bar) for A and B materials 4500 psi (31 MPa, 310 bar) for flushing fluid 100 psi (0.7 MPa, 7 bar) for heating fluid

Maximum fluid temperature . . . 180°F (82°C)

Fluid inlet . . . . . . . . . . . . . . . . . 3/4 in. npt and 3/4 in. x 1/2 in. nipple fittings for 3/4 in. x 1/2 in. hoses Fluid outlet size. . . . . . . . . . . . . 1/2 in. npt(m) nipple

Solvent inlet valves . . . . . . . . . . 1/4 in. npt(m) Heated fluid ports . . . . . . . . . . . 1/4 in. npt(f)

Wetted parts . . . . . . . . . . . . . . . Manifold block and internal parts: PTFE, electroless nickel plated steel, zinc plated steel

Flush valves and fittings: stainless steel, plated carbon steel, hardened alloy steel, acetal, PTFE

Fluid ball valves: plated carbon steel, acetal, PTFE, FKM

Fluid check valves: plated carbon steel, carbide seat, PTFE, alloy steel ball

3A2988B

21

Image 21 Contents
XM PFP Mix Manifold Related Manuals ContentsSkin Injection Hazard Equipment Misuse Hazard Changing Materials Keep Components a and B SeparateT2* U Component IdentificationTop View OverviewInstallation Grounding Flush Before Using EquipmentOperation Pressure Relief ProcedureFlush Dispensing and Spraying Lead/Lag Imbalance Volume Balancing the Mix ManifoldReference Formula Maintenance Clean Static MixersClean Mix Manifold Outlet Clean Mix Manifold Outlet, TroubleshootingCheck Valves RepairMix Manifold PartsMix Manifold Parts Technical Data Graco Information Graco Standard Warranty