Repair

Repair

Follow Pressure Relief Procedure, page 10, when you stop spraying and before cleaning, checking, ser- vicing, or transporting equipment. Read warnings in your sprayer manual.

NOTICE

Be sure to label all fluid parts A or B when disas- sembling them. Doing so prevents interchanging resin and hardener parts during reassembly, which will contaminate the materials and the fluid path through the equipment.

Color-coded chemically resistant tape may be used to label the parts. Use blue for resin and green for hardener.

Check Valves

When replacing material check valves or solvent check valves, reinstall with proper flow direction.

ti20094a

3A2988B

17

Image 17
Contents XM PFP Mix Manifold Related Manuals ContentsSkin Injection Hazard Equipment Misuse Hazard Changing Materials Keep Components a and B SeparateT2* U Component IdentificationTop View OverviewInstallation Grounding Flush Before Using EquipmentOperation Pressure Relief ProcedureFlush Dispensing and Spraying Lead/Lag Imbalance Volume Balancing the Mix ManifoldReference Formula Clean Mix Manifold Outlet MaintenanceClean Static Mixers Clean Mix Manifold Outlet, TroubleshootingCheck Valves RepairMix Manifold PartsMix Manifold Parts Technical Data Graco Information Graco Standard Warranty