Honeywell NXL user manual Control Keypad 5196, Indications on the Keypad display

Page 51

7

￿ ￿        

Control Keypad

51(96)

7.CONTROL KEYPAD

The control keypad is the link between the NXL frequency converter and the user. The NXL control

keypad features a seven-segment display with seven indicators for the Run status (RUN, , READY, STOP, ALARM, FAULT) and three indicators for the control place (I/O term, Keypad, Bus/Comm).

The control information, i.e. the number of menu, the displayed value and the numeric information are presented with numeric symbols.

The frequency converter is operable through the seven push-buttons of the control keypad. Furthermore, the keypad serves the purposes of parameter setting and value monitoring.

The keypad is detachable and isolated from the input line potential.

7.1Indications on the Keypad display

Figure 7-1. NXL control keypad and drive status indications

7.1.1Drive status indications

The drive status indications tell the user what the status of the motor and the drive is.

1

RUN

= Motor is running; Blinks when the stop command has been given but the

 

 

 

frequency is still ramping down.

2

,

=

Indicate the direction of motor rotation.

 

 

 

3

STOP

=

Indicates that the drive is not running.

4READY = Lights when AC power is on. In case of a fault, the symbol will not light up.

5ALARM = Indicates that the drive is running outside a certain limit and a warning is given.

6FAULT = Indicates that unsafe operating conditions were encountered due to which the drive was stopped.

Image 51
Contents NXL Hvac & Compact USER’S Manual Start-up Quick Guide Other NXL Manuals NXL Hvac Application Manual NXL Application Manuals Safety Control Keypad NXL Hvac Basic Speed Control Quick SetupEven if the motor is not running SafetySafety Safety instructions896 Safety Honeywell Earthing and earth fault protection Running the motorGeneral warning NXL frequency converter EMC classification EU DirectiveGeneral Technical criteriaHoneywell EMC classes and market requirements Manufacturers declaration of conformityNX EMC levels Product name EU Directive 1196Manufacturers name Manufacturers address1296 EU Directive Honeywell Receipt of Delivery Receipt of delivery 1396Type designation code NXL Compact Storage MaintenanceReceipt of delivery 1596 Warranty Technical Data 1696 Technical data HoneywellIntroduction          Technical data 1796NXL Compact Mains voltage 208 240 V & 380 500 Technical data 1996 Loadability Motor shaft powerNXL Hvac Mains voltage 380 500 2096 Technical data Honeywell Protections Technical data 2196Safety ConnectionsNXL Compact MF2 and MF3 Installation2296 Installation Honeywell Mounting2396 InstallationNXL Compact dimensions, MF3 2496 InstallationNXL Hvac MF4 MF6 Installation 2596Type Dimensions mm 2696 Installation Honeywell CoolingRemove this screw T1 V/T2 W/T3 Power connectionsCabling and Connections 2896 Cabling and connections HoneywellCabling St environmentCable type Cable and fuse sizes 3096 Cabling and connections HoneywellMounting of cable accessories Cabling and connections 3196Components 3296 Cabling and connections Honeywell Cabling and connections 3396 Installation instructionsStripping lengths of motor and mains cables 3496 Cabling and connections HoneywellMotor cable Mains cable Installation of cables to NXLCabling and connections 3596 Control cableBrake resistor Terminals 3696 Cabling and connections HoneywellRFI filter Cabling and connections 3796Dimensions WxHxD mm 13. NXL Hvac 03-12, MF4 Cabling and connections 3996Mains cable Motor cable 4096 Cabling and connections Honeywell17. NXL Hvac 38-61, MF6 Cabling and connections 4196Frame Tightening torque In-lbs Cable installation and the UL standards4296 Cabling and connections Honeywell Cable and motor insulation checksCabling and connections 4396 Control unit NXL Compact MF2 MF3Allowed option boards in NXL Hvac Control connections 4496 Cabling and connections HoneywellControl I/O Cabling and connections 4596Control terminal signals Terminal Signal Technical information4696 Cabling and connections Honeywell Jumper selections on NXL basic board Cabling and connections 4796Jumper block X 4896 Cabling and connections Honeywell24. The location of jumper blocks in MF2 left and MF3 right Cabling and connections 4996Motor thermistor PTC connection 5096 Cabling and connections HoneywellDrive status indications Control KeypadControl Keypad 5196 Indications on the Keypad display5296 Control Keypad Control place indicationsNumeric indications Reset Control Keypad 5396 Keypad push-buttonsButton descriptions Start Control Keypad HoneywellControl Keypad 5596 Navigation on the control keypad No editing 5796 Monitoring menu M1 5896 Control KeypadControl Keypad 5996 Parameter menu P2 6096 Control KeypadControl Keypad 6196    Selection of control place 6296 Control KeypadKeypad control menu K3 Parameters in Menu SelectionsControl Keypad 6396 Keypad has been selected as the active control placeActive control place 6496 Control Keypad Active faults menu F4Fault types Fault type symbol MeaningFault codes Fault Possible cause Correcting measures CodeControl Keypad 6596 6696 Control Keypad Control Keypad 6796 Fault history menu H5System menu S6 6896 Control Keypad6996 7096 Control Keypad Copy parametersSecurity Keypad settings 7196Left Hardware settings 7296 Control KeypadButton left Control Keypad 7396 System informationExample Counter 7496 Control KeypadControl Keypad 7596 ContentAI mode 7696 Control KeypadMF4 MF6 Control Keypad 7796 Modbus interfaceModbus RTU protocol Modbus process data 7896 Control KeypadTermination Resistor Modbus address areaBit Description Control Keypad 79968096 Control Keypad Fieldbus parametersXx.yyy Control Keypad 8196 Expander board menu E7Further keypad functions Running Commissioning8296 Commissioning Extremely dangerous and may cause death or severe injuryPush the Stop button on the keypad Commissioning 83968496 Commissioning Commissioning 8596 Basic parameters Column explanationsMonitoring values Control keypad menu M1 Hvac parameters in NXL Hvac Control keypad Menu P2 B2.1 8696 CommissioningBasic parameters Control keypad Menu P2 B2.1 / B2.1.15 Commissioning 8796DIN2 Fault TracingFault tracing 8996 Eeprom 9096 Fault tracing HoneywellFault tracing 9196 Terminals on Nxloptaa Description of Expander Board Nxloptaa9296 Honeywell Honeywell NXL board slot EExpander board Nxloptai 9396 Description of Expander Board NxloptaiDIN3 DIGINB.3 9496 Expander board Nxloptai HoneywellNXL Hvac Basic Speed Control Quick Setup Find out more

NXL specifications

Honeywell NXL is an advanced building management system designed to optimize the efficiency of HVAC, lighting, and security systems within commercial buildings. It incorporates cutting-edge technologies to enhance operational performance, improve energy savings, and provide a comfortable environment for occupants.

One of the standout features of Honeywell NXL is its integration capabilities. The system allows seamless connections between various subsystems, facilitating a unified approach to building management. This interoperability means that data from different systems can be aggregated, analyzed, and applied to enhance overall building performance.

The Honeywell NXL employs a user-friendly interface that empowers facility managers to easily navigate through critical information. The intuitive dashboard offers real-time analytics and visualizations, providing insights into energy consumption, system performance, and occupant comfort. Users can quickly identify inefficiencies and make informed decisions to improve operational effectiveness.

In terms of technologies, Honeywell NXL utilizes IoT connectivity, which enables devices and systems within the building to communicate with one another. This connectivity allows for remote monitoring and control, which is essential for effective facility management. By leveraging IoT technology, facility managers can receive alerts, conduct diagnostics, and perform maintenance proactively, reducing equipment downtime and avoiding costly repairs.

Another significant characteristic of the Honeywell NXL is its robust data analysis capabilities. The system collects vast amounts of data from sensors and connected devices, which is then processed to identify patterns and trends. This analytical approach not only aids in energy management but also enhances occupant comfort by adjusting parameters in real-time based on occupancy and environmental conditions.

Energy management is a critical issue for modern buildings, and Honeywell NXL addresses this with advanced optimization strategies. The system can implement demand response capabilities, adjusting energy usage based on peak periods or grid demands, ultimately saving costs and reducing environmental impact.

Moreover, Honeywell NXL places a strong emphasis on security features. Its design includes integrated surveillance and access control systems, ensuring the safety of occupants while facilitating efficient access management.

In summary, Honeywell NXL is a comprehensive building management solution that combines user-friendly design, IoT connectivity, advanced data analytics, energy optimization, and enhanced security features. Its ability to integrate various building systems makes it an essential tool for contemporary facility management, promoting efficiency and sustainability in building operations.