Honeywell NXL user manual Control Keypad, Button left, Hardware settings

Page 72

7

72(96)

Control Keypad

Honeywell

 

Timeout time (P6.6.3)

The Timeout time setting defines the time, after which the keypad display returns to the Default Page (P6.6.1), see above.

Move to the Edit menu by pressing the Menu button right. Set the timeout time you want and confirm the change with the Enter button. You can return to the previous step anytime by pushing the Menu

button left.

NOTE: This function cannot be disabled.

 

READY

 

READY

 

READY

 

STOP

I/O term

STOP

I/O term

STOP

I/O term

 

 

 

 

 

 

enter

CONFIRM CHANGE

 

 

 

 

 

 

CANCEL

 

 

s

 

s

 

 

 

 

 

 

nxlk24.fh8

 

 

Figure 7-13. Timeout time setting

7.4.7.4Hardware settings

In the Hardware settings submenu (S6.7) you can further customise the settings of the frequency converter with three parameters: Fan control, HMI acknowledgement timeout and HMI retry.

Fan control (P6.7.2)

Note! Only the higher power modules of MF3 have been equipped with a cooling fan, in lower power modules of MF3 the cooling fan is available as optional equipment.

If the cooling fan has been installed in MF3 it runs continuously, when the power is switched on.

NXL HVAC:

This function allows you to control the frequency converter’s cooling fan. You can set the fan to run continuously when the power is switched on or depending on the temperature of the unit. If the latter function has been selected the fan is switched on automatically when the heat sink temperature reaches 60°C. The fan receives a stop command when the heat sink temperature falls to 55°C. However the fan runs for about a minute after receiving the stop command, as well as after changing the value from 0 (Continuous) to 1 (Temperature).

Enter the edit mode by pushing the Menu button right. The present mode shown starts to blink. Use the Browser buttons to change the fan mode. Accept the change with the Enter button or return to the previous level with the Menu button left.

Image 72
Contents NXL Hvac & Compact USER’S Manual Start-up Quick Guide Other NXL Manuals NXL Hvac Application Manual NXL Application Manuals Safety NXL Hvac Basic Speed Control Quick Setup Control KeypadSafety SafetySafety instructions Even if the motor is not running896 Safety Honeywell Earthing and earth fault protection Running the motorGeneral warning EU Directive GeneralTechnical criteria NXL frequency converter EMC classificationHoneywell EMC classes and market requirements Manufacturers declaration of conformityNX EMC levels EU Directive 1196 Manufacturers nameManufacturers address Product name1296 EU Directive Honeywell Receipt of Delivery Receipt of delivery 1396Type designation code NXL Compact Maintenance StorageReceipt of delivery 1596 Warranty Technical Data 1696 Technical data HoneywellIntroduction Technical data 1796         NXL Compact Mains voltage 208 240 V & 380 500 Technical data 1996 Loadability Motor shaft powerNXL Hvac Mains voltage 380 500 2096 Technical data Honeywell Technical data 2196 SafetyConnections ProtectionsInstallation 2296 Installation HoneywellMounting NXL Compact MF2 and MF3Installation 23962496 Installation NXL Compact dimensions, MF3Installation 2596 NXL Hvac MF4 MF62696 Installation Honeywell Cooling Type Dimensions mmRemove this screw Power connections Cabling and Connections2896 Cabling and connections Honeywell T1 V/T2 W/T3Cabling St environmentCable type 3096 Cabling and connections Honeywell Cable and fuse sizesMounting of cable accessories Cabling and connections 3196Components 3296 Cabling and connections Honeywell Installation instructions Cabling and connections 33963496 Cabling and connections Honeywell Stripping lengths of motor and mains cablesInstallation of cables to NXL Cabling and connections 3596Control cable Motor cable Mains cable3696 Cabling and connections Honeywell Brake resistor TerminalsCabling and connections 3796 RFI filterDimensions WxHxD mm Cabling and connections 3996 13. NXL Hvac 03-12, MF44096 Cabling and connections Honeywell Mains cable Motor cableCabling and connections 4196 17. NXL Hvac 38-61, MF6Cable installation and the UL standards 4296 Cabling and connections HoneywellCable and motor insulation checks Frame Tightening torque In-lbsCabling and connections 4396 Control unit NXL Compact MF2 MF3Allowed option boards in NXL Hvac 4496 Cabling and connections Honeywell Control connectionsCabling and connections 4596 Control I/OControl terminal signals Terminal Signal Technical information4696 Cabling and connections Honeywell Cabling and connections 4796 Jumper selections on NXL basic board4896 Cabling and connections Honeywell Jumper block XCabling and connections 4996 24. The location of jumper blocks in MF2 left and MF3 right5096 Cabling and connections Honeywell Motor thermistor PTC connectionControl Keypad Control Keypad 5196Indications on the Keypad display Drive status indications5296 Control Keypad Control place indicationsNumeric indications Reset Control Keypad 5396 Keypad push-buttonsButton descriptions Control Keypad Honeywell StartControl Keypad 5596 Navigation on the control keypad No editing 5796 5896 Control Keypad Monitoring menu M1Control Keypad 5996 6096 Control Keypad Parameter menu P2    Control Keypad 61966296 Control Keypad Keypad control menu K3Parameters in Menu Selections Selection of control placeControl Keypad 6396 Keypad has been selected as the active control placeActive control place Active faults menu F4 Fault typesFault type symbol Meaning 6496 Control KeypadFault codes Fault Possible cause Correcting measures CodeControl Keypad 6596 6696 Control Keypad Fault history menu H5 Control Keypad 67966896 Control Keypad System menu S66996 7096 Control Keypad Copy parametersSecurity Keypad settings 7196Left Hardware settings 7296 Control KeypadButton left Control Keypad 7396 System informationExample 7496 Control Keypad CounterContent Control Keypad 7596AI mode 7696 Control KeypadMF4 MF6 Control Keypad 7796 Modbus interfaceModbus RTU protocol 7896 Control Keypad Termination ResistorModbus address area Modbus process dataControl Keypad 7996 Bit Description8096 Control Keypad Fieldbus parametersXx.yyy Control Keypad 8196 Expander board menu E7Further keypad functions Commissioning 8296 CommissioningExtremely dangerous and may cause death or severe injury RunningCommissioning 8396 Push the Stop button on the keypad8496 Commissioning Commissioning 8596 Basic parameters Column explanationsMonitoring values Control keypad menu M1 8696 Commissioning Hvac parameters in NXL Hvac Control keypad Menu P2 B2.1Commissioning 8796 Basic parameters Control keypad Menu P2 B2.1 / B2.1.15Fault Tracing DIN2Fault tracing 8996 9096 Fault tracing Honeywell EepromFault tracing 9196 Description of Expander Board Nxloptaa 9296 HoneywellHoneywell NXL board slot E Terminals on NxloptaaDescription of Expander Board Nxloptai Expander board Nxloptai 93969496 Expander board Nxloptai Honeywell DIN3 DIGINB.3NXL Hvac Basic Speed Control Quick Setup Find out more

NXL specifications

Honeywell NXL is an advanced building management system designed to optimize the efficiency of HVAC, lighting, and security systems within commercial buildings. It incorporates cutting-edge technologies to enhance operational performance, improve energy savings, and provide a comfortable environment for occupants.

One of the standout features of Honeywell NXL is its integration capabilities. The system allows seamless connections between various subsystems, facilitating a unified approach to building management. This interoperability means that data from different systems can be aggregated, analyzed, and applied to enhance overall building performance.

The Honeywell NXL employs a user-friendly interface that empowers facility managers to easily navigate through critical information. The intuitive dashboard offers real-time analytics and visualizations, providing insights into energy consumption, system performance, and occupant comfort. Users can quickly identify inefficiencies and make informed decisions to improve operational effectiveness.

In terms of technologies, Honeywell NXL utilizes IoT connectivity, which enables devices and systems within the building to communicate with one another. This connectivity allows for remote monitoring and control, which is essential for effective facility management. By leveraging IoT technology, facility managers can receive alerts, conduct diagnostics, and perform maintenance proactively, reducing equipment downtime and avoiding costly repairs.

Another significant characteristic of the Honeywell NXL is its robust data analysis capabilities. The system collects vast amounts of data from sensors and connected devices, which is then processed to identify patterns and trends. This analytical approach not only aids in energy management but also enhances occupant comfort by adjusting parameters in real-time based on occupancy and environmental conditions.

Energy management is a critical issue for modern buildings, and Honeywell NXL addresses this with advanced optimization strategies. The system can implement demand response capabilities, adjusting energy usage based on peak periods or grid demands, ultimately saving costs and reducing environmental impact.

Moreover, Honeywell NXL places a strong emphasis on security features. Its design includes integrated surveillance and access control systems, ensuring the safety of occupants while facilitating efficient access management.

In summary, Honeywell NXL is a comprehensive building management solution that combines user-friendly design, IoT connectivity, advanced data analytics, energy optimization, and enhanced security features. Its ability to integrate various building systems makes it an essential tool for contemporary facility management, promoting efficiency and sustainability in building operations.