AUTO-CLOSE TIMER

AUTO-CLOSE TIMER

PROGRAMMING

This function is not available for the North American market.

The factory set Auto-Close timer delay is 15 seconds.

In order to confirm the operation of the Auto- Close timer first set DIP switch No. 4 to ON. Then press the case push button to open the door. The door will open and re-close after the time delay. The factory preset time delay is 15 seconds.

To change the Auto-Close time delay proceed as follows:

1.Close the door.

2.Set DIP switch No. 4 to the ON position.

3.Press and hold the program button.

4.Release the button after the SECOND flash or beep.

5.Press the OPEN push button.

6.After the door has fully opened and after the required delay press the CLOSE push button. This new delay will now be stored into the memory and retained during any power interruptions.

A sequence of 6 flashes and beeps follow to prompt you to decide if you want the door to

Auto-Close regardless of the door re-opening after striking an obstruction.

It is preferable that the door should re-open and stay open following an obstruction strike. However it may be required for security reasons that the door should Auto-Close after re-opening, after hitting a large build-up of snow and ice in winter, in which case it will make two attempts to close onto the ice. If the snow and ice has not compressed then on the third run it will then stop on the ice.

If the door is required to Auto-Close regardless of such an obstruction then press the close button a second time during the 6 flashes and bleeps.

If the CLOSE button is not pressed during the flashes and beeps the controller will default to stay open after an obstruction re-open sequence.

If it is required to change the programmed delay then repeat the programming sequence.

If a Zap Radio Remote Control system is fitted and the Auto-Close function is enabled then operation of the transmitter will only open the door. The door will close after the programmed time delay.

Whilst the door is open, the close delay is reset each time the Zap transmitter is operated and each time a safety circuit or Photo-Eye is activated.