IMPORTANT INSTALLATION

IMPORTANT INSTALLATION

INSTRUCTIONS

WARNING:

To reduce the risk of Injury or death

READ AND FOLLOW ALL

INSTALLATION INSTRUCTIONS

Install only on a properly balanced door. An improperly balanced door has the potential to inflict severe injury. Have a qualified service person make repairs to cables, spring assemblies, and other hardware before installing the opener.

Remove all ropes and remove, or make inoperative, all locks connected to the garage door before installing opener.

Where possible, install the door opener 7ft (2.1m) or more above the floor. Mount the emergency Manual Over-Ride Lever 6ft (1.8m) above the floor.

Do not connect the opener to power until instructed to do so.

Locate the control unit:

(a): Within sight of the door,

(b): At a min height of 5ft so small children cannot reach it, and

(c): Away from all moving parts.

Install the entrapment label next to the control button in a prominent location using a suitable secure mechanical means if necessary. Attach the emergency release marking on the emergency release cable or next to the emergency release.

After installing the opener, the door must reverse when it contacts a 11/2” high object (or a 2” by 4” board laid on the floor).

The maximum door size should not exceed 160 square feet

(15 sq mtrs). The maximum door weight should not exceeed 500 pounds (230 Kgm).

FOR INTERNAL INSTALLATION ONLY

Page 3