Zap 815-RL installation instructions Fault Finding Guide, Reason & Remedy

Models: 815-RL

1 28
Download 28 pages 63.62 Kb
Page 27
Image 27
FAULT FINDING GUIDE

 

 

FAULT FINDING GUIDE

 

 

 

FAULT

 

REASON & REMEDY

1. The door stops just

 

A. The door movement is stiff due to the door running tight against

after it has started in

 

the door frame in the fully closed position. In which case adjust the

the open direction.

 

position of the roller wheel supports to ease the pressure of the

 

 

door against the frame.

 

 

B. The door is badly out of balance. In which case re-tension the

 

 

counterbalance springs.

 

 

C. The door is near the maximum weight for the operator and the

 

 

Maximum Motor Current adjuster is set too low. In which case turn

 

 

the adjuster a further 20 degrees counter-clockwise.

 

 

 

2. The closing door

 

A. There is an abnormality in the track, which is causing the roller

stops and reopens

 

wheels to jump. This may be due to a misalignment of track

before it contacts the

 

sections or a deformity of a damaged section of track. In which

ground.

 

case correct the track problem and ensure the door will run

 

 

smoothly by hand movement with the over-ride lever disengaged.

 

 

B. The Close Sensitivity adjuster is set too fine. In which case turn the

 

 

adjuster counter-clockwise by a further 20 degrees.

 

 

 

22

Page 27
Image 27
Zap 815-RL installation instructions Fault Finding Guide, Reason & Remedy