Parameters are the way of conveying the commands of the user to the frequency converter. The parameter values can be edited by entering the Parameter Menu from the Main Menu when the location indication P2 is visible on the display. The value editing procedure is presented in Figure 7- 6.

Push the Menu button right once to move into the Parameter Group Menu (G#). Locate the parameter group desired by using the Browser buttons and push the Menu button right again to enter the group and its parameters. Use again the Browser buttons to find the parameter (P#) you want to edit. Pushing the Menu button right takes you to the edit mode. As a sign of this, the parameter value starts to blink. You can now change the value in two different manners:

1Just set the new desired value with the Browser buttons and confirm the change with the Enter button. Consequently, the blinking stops and the new value is visible in the value field.

2Push the Menu button right once again. Now you will be able to edit the value digit by digit. This editing manner may come in handy, when a relatively greater or smaller value than that on the display is desired. Confirm the change with the Enter button.

The value will not change unless the Enter button is pushed. Pressing the Menu button left

takes you back to the previous menu.

Several parameters are locked, i.e. not editable, when the drive is in RUN status. The frequency converter must be stopped in order to edit these parameters.

The parameters values can also be locked using the function in menu S6 (see Chapter 7.4.7.2).

You can return to the Main menu anytime by pressing the Menu button left for 1—2 seconds.

The basic parameters are listed in Chapter 8.3. You will find the complete parameter lists and descriptions in the HVAC and Multi-Control Application manuals.

Once in the last parameter of a parameter group, you can move directly to the first parameter of that group by pushing the Browser button up.

Image 60
Contents NXL Hvac & Compact USER’S Manual Start-up Quick Guide Other NXL Manuals NXL Hvac Application Manual NXL Application Manuals Safety NXL Hvac Basic Speed Control Quick Setup Control KeypadSafety SafetySafety instructions Even if the motor is not running896 Safety Honeywell Earthing and earth fault protection Running the motorGeneral warning EU Directive GeneralTechnical criteria NXL frequency converter EMC classificationHoneywell EMC classes and market requirements Manufacturers declaration of conformityNX EMC levels EU Directive 1196 Manufacturers nameManufacturers address Product name1296 EU Directive Honeywell Receipt of Delivery Receipt of delivery 1396Type designation code NXL Compact Maintenance StorageReceipt of delivery 1596 Warranty Technical Data 1696 Technical data HoneywellIntroduction Technical data 1796         NXL Compact Mains voltage 208 240 V & 380 500 Technical data 1996 Loadability Motor shaft powerNXL Hvac Mains voltage 380 500 2096 Technical data Honeywell Technical data 2196 SafetyConnections ProtectionsInstallation 2296 Installation HoneywellMounting NXL Compact MF2 and MF3Installation 23962496 Installation NXL Compact dimensions, MF3Installation 2596 NXL Hvac MF4 MF62696 Installation Honeywell Cooling Type Dimensions mmRemove this screw Power connections Cabling and Connections2896 Cabling and connections Honeywell T1 V/T2 W/T3Cabling St environmentCable type 3096 Cabling and connections Honeywell Cable and fuse sizesMounting of cable accessories Cabling and connections 3196Components 3296 Cabling and connections Honeywell Installation instructions Cabling and connections 33963496 Cabling and connections Honeywell Stripping lengths of motor and mains cablesInstallation of cables to NXL Cabling and connections 3596Control cable Motor cable Mains cable3696 Cabling and connections Honeywell Brake resistor TerminalsCabling and connections 3796 RFI filterDimensions WxHxD mm Cabling and connections 3996 13. NXL Hvac 03-12, MF44096 Cabling and connections Honeywell Mains cable Motor cableCabling and connections 4196 17. NXL Hvac 38-61, MF6Cable installation and the UL standards 4296 Cabling and connections HoneywellCable and motor insulation checks Frame Tightening torque In-lbsCabling and connections 4396 Control unit NXL Compact MF2 MF3Allowed option boards in NXL Hvac 4496 Cabling and connections Honeywell Control connectionsCabling and connections 4596 Control I/OControl terminal signals Terminal Signal Technical information4696 Cabling and connections Honeywell Cabling and connections 4796 Jumper selections on NXL basic board4896 Cabling and connections Honeywell Jumper block XCabling and connections 4996 24. The location of jumper blocks in MF2 left and MF3 right5096 Cabling and connections Honeywell Motor thermistor PTC connectionControl Keypad Control Keypad 5196Indications on the Keypad display Drive status indications5296 Control Keypad Control place indicationsNumeric indications Reset Control Keypad 5396 Keypad push-buttonsButton descriptions Control Keypad Honeywell StartControl Keypad 5596 Navigation on the control keypad No editing 5796 5896 Control Keypad Monitoring menu M1Control Keypad 5996 6096 Control Keypad Parameter menu P2    Control Keypad 61966296 Control Keypad Keypad control menu K3Parameters in Menu Selections Selection of control placeControl Keypad 6396 Keypad has been selected as the active control placeActive control place Active faults menu F4 Fault typesFault type symbol Meaning 6496 Control KeypadFault codes Fault Possible cause Correcting measures CodeControl Keypad 6596 6696 Control Keypad Fault history menu H5 Control Keypad 67966896 Control Keypad System menu S66996 7096 Control Keypad Copy parametersSecurity Keypad settings 7196Left Hardware settings 7296 Control KeypadButton left Control Keypad 7396 System informationExample 7496 Control Keypad CounterContent Control Keypad 7596AI mode 7696 Control KeypadMF4 MF6 Control Keypad 7796 Modbus interfaceModbus RTU protocol 7896 Control Keypad Termination ResistorModbus address area Modbus process dataControl Keypad 7996 Bit Description8096 Control Keypad Fieldbus parametersXx.yyy Control Keypad 8196 Expander board menu E7Further keypad functions Commissioning 8296 CommissioningExtremely dangerous and may cause death or severe injury RunningCommissioning 8396 Push the Stop button on the keypad8496 Commissioning Commissioning 8596 Basic parameters Column explanationsMonitoring values Control keypad menu M1 8696 Commissioning Hvac parameters in NXL Hvac Control keypad Menu P2 B2.1Commissioning 8796 Basic parameters Control keypad Menu P2 B2.1 / B2.1.15Fault Tracing DIN2Fault tracing 8996 9096 Fault tracing Honeywell EepromFault tracing 9196 Description of Expander Board Nxloptaa 9296 HoneywellHoneywell NXL board slot E Terminals on NxloptaaDescription of Expander Board Nxloptai Expander board Nxloptai 93969496 Expander board Nxloptai Honeywell DIN3 DIGINB.3NXL Hvac Basic Speed Control Quick Setup Find out more

NXL specifications

Honeywell NXL is an advanced building management system designed to optimize the efficiency of HVAC, lighting, and security systems within commercial buildings. It incorporates cutting-edge technologies to enhance operational performance, improve energy savings, and provide a comfortable environment for occupants.

One of the standout features of Honeywell NXL is its integration capabilities. The system allows seamless connections between various subsystems, facilitating a unified approach to building management. This interoperability means that data from different systems can be aggregated, analyzed, and applied to enhance overall building performance.

The Honeywell NXL employs a user-friendly interface that empowers facility managers to easily navigate through critical information. The intuitive dashboard offers real-time analytics and visualizations, providing insights into energy consumption, system performance, and occupant comfort. Users can quickly identify inefficiencies and make informed decisions to improve operational effectiveness.

In terms of technologies, Honeywell NXL utilizes IoT connectivity, which enables devices and systems within the building to communicate with one another. This connectivity allows for remote monitoring and control, which is essential for effective facility management. By leveraging IoT technology, facility managers can receive alerts, conduct diagnostics, and perform maintenance proactively, reducing equipment downtime and avoiding costly repairs.

Another significant characteristic of the Honeywell NXL is its robust data analysis capabilities. The system collects vast amounts of data from sensors and connected devices, which is then processed to identify patterns and trends. This analytical approach not only aids in energy management but also enhances occupant comfort by adjusting parameters in real-time based on occupancy and environmental conditions.

Energy management is a critical issue for modern buildings, and Honeywell NXL addresses this with advanced optimization strategies. The system can implement demand response capabilities, adjusting energy usage based on peak periods or grid demands, ultimately saving costs and reducing environmental impact.

Moreover, Honeywell NXL places a strong emphasis on security features. Its design includes integrated surveillance and access control systems, ensuring the safety of occupants while facilitating efficient access management.

In summary, Honeywell NXL is a comprehensive building management solution that combines user-friendly design, IoT connectivity, advanced data analytics, energy optimization, and enhanced security features. Its ability to integrate various building systems makes it an essential tool for contemporary facility management, promoting efficiency and sustainability in building operations.