Harbor Freight Tools 95498 operating instructions Operating Instructions, To Start The Compressor

Page 10

OPERATING INSTRUCTIONS

To Start The Compressor:

 

 

 

 

 

 

REGULATOR

 

 

 

 

 

 

 

(67)

 

 

 

PRESSURE SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

(64)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

 

 

 

 

 

 

OUTLET

 

 

 

 

 

 

 

VALVE

 

 

 

 

 

 

TANK

 

 

 

 

 

 

 

 

 

(68)

 

 

 

 

 

 

 

 

 

PRESSURE

 

 

 

 

 

 

 

 

 

 

 

 

 

GAUGE

AIR HOSE

 

TOOL

 

 

 

 

 

(63)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(NOT INCLUDED)

 

 

 

 

 

 

 

 

PRESSURE

 

 

 

SAFETY

 

 

 

 

 

 

 

GAUGE

 

 

 

RELEASE

 

 

(66)

 

 

 

 

 

 

 

 

VALVE

 

 

 

 

 

 

 

 

 

(62)

TANK DRAIN VALVE

(52)

FIGURE F

1.Check to make sure the Air Tank’s Drain Valve (52), located on the bottom Air Tank (51), is fully closed.

2.Turn the Air Outlet Valve (68) to its closed position.

3.Connect an air hose (not included) to the previously installed Quick Connector. Then, connect the other end of the air hose to the pneumatic tool (not included).

4.Plug the Power Cord (55) into the nearest 120 volt, grounded, electrical outlet.

5.Pull up on the Pressure Switch (64) to its “START” position to turn on the unit.

6.When the Tank Pressure Gauge (63) reaches at least 85 PSI, turn the Air Outlet Valve to its open position to allow air to the pneumatic tool.

7.Once the air pressure reaches the pneumatic tool, observe the Tool Pressure Gauge (66). Adjust the Regulator (67) to feed the proper PSI to the tool. To do so, turn the Regulator clockwise to increase the PSI. Turn the Regulator counterclock- wise to decrease the PSI.

Note: When the maximum air pressure, 115 PSI, is reached as indicated by the Tank Pressure Gauge (63), the motor will stop. The Compressor will automatically re- start when the air pressure drops below 85 PSI.

IMPORTANT: To decompress the air pressure in the Air Tanks (51), push down on the Pressure Switch (64) to its “STOP” position. Then, pull out on the Safety Release Valve to immediately release air pressure from the Air Tanks.

SKU 95498

For technical questions, please call 1-800-444-3353.

Page 10

Image 10
Contents Your Warranty Is Voided If For technical questions or replacement parts, please callPersonal Safety Product SpecificationsGeneral Safety Rules and Precautions Save this ManualService Tool USE and CareSpecific Safety Rules and Precautions For technical questions, please call Grounding Symbology UnpackingAssembly Instructions See Figure DTo Add Compressor Oil PRE-START InstructionsSee Figure E Operating Instructions To Start The CompressorTo Stop The Compressor SKU For technical questions, please callTroubleshooting INSPECTION, MAINTENANCE, and CleaningProblem Possible Cause Part Description Parts ListPlease Read the Following Carefully SKU 95498 For technical questions, please callAssembly Diagram Limited 1 year / 90 day Warranty