Bryant 538MNC, 538MAC, 538MNQ, 538MAQ, 619MAQ, 619MAC, 619MNC, 619MNQ Safety Precautions, General

Page 2

SAFETY PRECAUTIONS

!WARNING

PERSONAL INJURY, DEATH, OR PROPERTY

DAMAGE HAZARD

Failure to follow this warning could result in personal injury, death, or property damage.

Read and follow all instructions and warnings, including labels shipped with or attached to unit before operating your new air conditioner.

Any time you see this symbol in manuals, instructions and on the unit, be aware of the potential for personal injury. There are three levels of precaution:

DANGER identifies the most serious hazards which will result in severe personal injury or death.

WARNING signifies hazards that could result in personal injury or death.

CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage.

NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

!WARNING

PERSONAL INJURY, DEATH AND / OR PROPERTY

DAMAGE HAZARD

Failure to follow this warning could result in personal injury, death or property damage.

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage.

Consult a qualified installer, service agency, your distributor or branch for information or assistance. The qualified installer or service agency must use factory-authorized kits or accessories when modifying this product.

GENERAL

The high wall fan coil unit provides quiet, maximum comfort. In addition to cooling and/or heating, the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort.

IMPORTANT: The high wall fan coil unit should be installed by authorized personnel only; using approved tubing and accessories. If technical assistance, service or repair is needed, contact the installer or call 1-800-428-4326.

The high wall fan coil unit can be set up and operated from the remote control (provided). If the remote is misplaced, the system can be operated from the “Auto” setting on the unit.

Operating Modes:

The high wall fan coil unit has five operating modes.

SFan only

SAuto (heat pump models only)

SHeating (heat pump models only)

SCooling

SDehumidification (DRY)

Fan Only

In Fan Only mode, the system filters and circulates room air without changing room air temperature.

Auto

In Auto mode, the system will automatically cool or heat the room according to the user-selected set point.

Heating

In Heating mode, the system heats and filters room air.

Cooling

In Cooling mode, the system cools, dries and filters room air.

Dehumidification (DRY)

In Dehumidification mode, the system dries, filters and slightly cools room air temperature. This mode does not take the place of a dehumidifier.

Remote Control

The remote control transmits commands to set up and operate the system. The control has a window display panel that shows the current system status. The control can be secured to a surface when used with the mounting bracket provided.

2

Image 2
Contents HIGH-WALL DUCT-FREE Split System Safety Precautions GeneralIndoor/Outdoor Unit Remote ControlPart Names Operation TimerUnit Display Panels Equipment Damage Hazard Remote ControlBattery Installation Unit Operation HazardSetting the Room Temperature Set Point Remote Control FunctionsSelecting an Operating Mode Emergency OperationTimer OFF only Timer FunctionTimer on only Selecting the Fan SpeedTurbo Mode Timer on and Timer OFFSleep Mode Resetting the Remote ControlCLEANING, Maintenance and Troubleshooting Periodic Maintenance Troubleshooting