Timer ON and Timer OFF
AUTO
SET TEMP.
CLOCK
TIMER ON
TIMER OFF
SPEED AUTO
A08041
Use both functions to program the unit to turn on and shut off at specified times.
UNIT OFF
-Set TIMER ON as previously described.
-Set TIMER OFF as previously described.
-The unit will start automatically at the set TIME ON and will turn off at the set TIME OFF.
UNIT ON
-Set TIME OFF as previously described.
-Set TIME ON as previously described.
-The unit will turn off automatically at the set TIME OFF and will turn on at the set TIME ON.
Sleep Mode
This mode is used to conserve energy and can be used when the unit is in the COOL, HEAT or AUTO mode only.
Cool Mode
-Push the SLEEP button. The SLEEP display will appear on the remote control.
COOL
SET TEMP.
CLOCK
SPEED AUTO
A08038
-After 1 hour the set point will be raised by 1.8_F (1_C).
-After another hour, the set point will be raised by another 1.8_F (1_C) and the fan will run in low speed.
-The unit will shut off 7 hours after setting the SLEEP mode.
-The SLEEP mode will be cancelled if any button on the remote control is pressed.
Heat Mode
-Same as cooling mode but set points will be lowered by 1.8_F (1_C).
Turbo Mode
This function is available in COOL mode on 9k and 12k cooling only units. Use the TURBO mode to cool the room rapidly.
-Press the TURBO button. An audible “beep” will be heard.
-The fan will run on high speed.
-The TURBO mode terminates automatically after 20 minutes from pushing the Turbo mode button once. It can be terminated immediately by pushing the Turbo mode again. When the Turbo mode is terminated, the unit will go back to the original setting.
Lock
Use this function to lock the settings on the remote control and to prevent the settings being changed.
COOL |
|
SET TEMP. | CLOCK |
| |
SPEED AUTO | LOCK SYMBOL |
A08039
To lock and unlock the remote control, press the Y and B temp buttons simultaneously for about 3 seconds.
Resetting the Remote Control
If the remote control is not functioning properly, it can be reset by pressing the reset button with a paper clip or tip of a pen. Current settings will be cancelled and the control will return to the initial settings and will be in standby mode. Push the ON/OFF button to activate it.
Time Delay
If the On/Off button is pressed too soon after a stop, the compressor will not start for 3 minutes due to the inherent protection against frequent compressor cycling. The unit will only emit an audible beep when the signals are received correctly.
Heating Features
If the unit is in the heating mode, there will be a delay when the fan starts. The fan will start only after the coil is warmed up to prevent cold blow.
Defrost Operation
In heating mode, if the outdoor coil is frosted, the indoor fan and outdoor fan will turn off while system removes the frost on the outdoor coil.
The system will automatically revert to normal operation when frost is removed from the outdoor unit.
Auto Start
If the power fails while the unit is operating, the unit stores the operating condition, and it will start operation automatically under those conditions when the power is restored.
8