Pelco C1498M-B operation manual Limit Stops, Park Time Minutes

Page 17

NOTE: Programming preset 90 (23) disables the manual limit stops until preset 91 (24) is set.

NOTE: On power-up, the auto scan tilt angle will be whatever angle the camera was at when the right scan limit was set.

NOTE: Preset 1 must be programmed for the dome to park.

LIMIT STOPS

The two types of limit stop are manual and scan. When manual limit stops are set, a manual (joystick) pan operation stops when a limit is reached. When scan limit stops are set, the dome reverses direction during random, frame, and auto scanning when a limit stop is reached. Software controls limit stops. To set limit stops:

1.Turn on limit stop mode.

2.Program the limit stops.

Turning Limit Stops On or Off

To change the limit stop mode:

1.On the main menu, move the joystick up or down to position the cursor (>) beside Other.

2.Press the Iris Open button to enter the Other submenu.

3.Move the joystick up or down to position the cursor beside Limit Stops.

4.Press the Iris Open button. The cursor moves to the right beside the word On or Off.

5.Move the joystick up or down to toggle between On and Off.

6.SELECT – Press the Iris Open button to select your choice.

CANCEL– Press the Iris Close button if you do not want to change the setting.

Programming Limit Stops

MANUAL LIMIT STOPS

Refer to the documentation for your control system for programming presets, then do the following:

1.Make sure limit stops are turned ON (refer to the Limit Stops section), then exit the menu.

2.Push the joystick left until you reach the limit you want the camera to go to on the left.

3.Program preset 90 (23).

4.Push the stick right to the limit you want the camera to go to on the right.

5.Program preset 91 (24).

Setting presets 90 (23) and 91 (24) to the same point disables manual limit stops.

SCAN LIMIT STOPS

Refer to the documentation for your control system for programming presets, then do the following:

1.Make sure limit stops are turned ON (refer to the Limit Stops section), then exit the menu.

2.Push the joystick left until you reach the limit you want the camera to go to on the left.

3.Program preset 92 (25).

4.Push the joystick right to the limit you want the camera to go to on the right.

5.Program preset 93 (26).

Setting presets 92 (25) and 93 (26) to the same point disables scan limit stops.

PARK TIME MINUTES

This feature parks the dome at preset 1 after a programmed number of minutes of control inactivity. You can set the time from 1 to 720 minutes (12 hours). Setting the time to zero disables this feature. To change the park time:

1.On the main menu, move the joystick up or down to position the cursor (>) beside Other.

2.Press the Iris Open button to enter the Other submenu.

3.Move the joystick up or down to position the cursor beside Park Time Minutes.

4.Press the Iris Open button. The cursor moves to the right beside the current park time.

5.Move the joystick up or down to change the park time.

6.SELECT – Press the Iris Open button to select your choice.

CANCEL – Press the Iris Close button if you do not want to change the setting.

SCAN SPEED

Scan speed is adjustable from 1-40 degrees per second, and occurs in three scan modes: auto, random, and frame. To change the scan speed:

1.On the main menu, move the joystick up or down to position the cursor (>) beside Other.

2.Press the Iris Open button to enter the Other submenu.

Pelco Manual C1498M-B (7/99)

17

Image 17
Contents Listed Contents Installation Important Safeguards and WarningsDescription ModelsTable B. Switch Settings for SW2 P-Type Control Table C. Switch Settings for SW2 D-Type Control OFF 113 169 Operation POWER-UP DisplayPAN and Tilt Functions Preset FunctionsAuto Flip Scan SpeedProgramming the Spectra Lite Main Menu AccessPark Backlight Compensation Reset CameraCM9750 CM9760Auto Iris GAIN/AGC Shutter Speed AUTO-FOCUS ModeLine Synchronization SharpnessWhite Balance POWER-UP Mode Park Time Minutes Limit StopsSymptom Unit or fan does not operate TroubleshootingBack BOX Electronic Assembly Removal SpecificationsRegulatory Notices Warranty and Return Information