Table C. Switch Settings for SW2 – D-Type Control (Continued)

NOTE: For Coaxitron® controls, SW2 is not used; set all switches OFF.

For P-type control systems, refer to Table B.

Receiver Address

 

 

 

Switch Setting

 

 

 

 

SW2-1

SW2-2

SW2-3 SW2-4 SW2-5

SW2-6

SW2-7 SW2-8

 

 

 

 

 

 

 

 

 

113

ON

OFF

OFF

OFF

ON

ON

ON

OFF

114

OFF

ON

OFF

OFF

ON

ON

ON

OFF

115

ON

ON

OFF

OFF

ON

ON

ON

OFF

116

OFF

OFF

ON

OFF

ON

ON

ON

OFF

117

ON

OFF

ON

OFF

ON

ON

ON

OFF

118

OFF

ON

ON

OFF

ON

ON

ON

OFF

119

ON

ON

ON

OFF

ON

ON

ON

OFF

120

OFF

OFF

OFF

ON

ON

ON

ON

OFF

121

ON

OFF

OFF

ON

ON

ON

ON

OFF

122

OFF

ON

OFF

ON

ON

ON

ON

OFF

123

ON

ON

OFF

ON

ON

ON

ON

OFF

124

OFF

OFF

ON

ON

ON

ON

ON

OFF

125

ON

OFF

ON

ON

ON

ON

ON

OFF

126

OFF

ON

ON

ON

ON

ON

ON

OFF

127

ON

ON

ON

ON

ON

ON

ON

OFF

128

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

129

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

130

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

131

ON

ON

OFF

OFF

OFF

OFF

OFF

ON

132

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

133

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

134

OFF

ON

ON

OFF

OFF

OFF

OFF

ON

135

ON

ON

ON

OFF

OFF

OFF

OFF

ON

136

OFF

OFF

OFF

ON

OFF

OFF

OFF

ON

137

ON

OFF

OFF

ON

OFF

OFF

OFF

ON

138

OFF

ON

OFF

ON

OFF

OFF

OFF

ON

139

ON

ON

OFF

ON

OFF

OFF

OFF

ON

140

OFF

OFF

ON

ON

OFF

OFF

OFF

ON

141

ON

OFF

ON

ON

OFF

OFF

OFF

ON

142

OFF

ON

ON

ON

OFF

OFF

OFF

ON

143

ON

ON

ON

ON

OFF

OFF

OFF

ON

144

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

145

ON

OFF

OFF

OFF

ON

OFF

OFF

ON

146

OFF

ON

OFF

OFF

ON

OFF

OFF

ON

147

ON

ON

OFF

OFF

ON

OFF

OFF

ON

148

OFF

OFF

ON

OFF

ON

OFF

OFF

ON

149

ON

OFF

ON

OFF

ON

OFF

OFF

ON

150

OFF

ON

ON

OFF

ON

OFF

OFF

ON

151

ON

ON

ON

OFF

ON

OFF

OFF

ON

152

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

153

ON

OFF

OFF

ON

ON

OFF

OFF

ON

154

OFF

ON

OFF

ON

ON

OFF

OFF

ON

155

ON

ON

OFF

ON

ON

OFF

OFF

ON

156

OFF

OFF

ON

ON

ON

OFF

OFF

ON

157

ON

OFF

ON

ON

ON

OFF

OFF

ON

158

OFF

ON

ON

ON

ON

OFF

OFF

ON

159

ON

ON

ON

ON

ON

OFF

OFF

ON

160

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

161

ON

OFF

OFF

OFF

OFF

ON

OFF

ON

162

OFF

ON

OFF

OFF

OFF

ON

OFF

ON

163

ON

ON

OFF

OFF

OFF

ON

OFF

ON

164

OFF

OFF

ON

OFF

OFF

ON

OFF

ON

165

ON

OFF

ON

OFF

OFF

ON

OFF

ON

166

OFF

ON

ON

OFF

OFF

ON

OFF

ON

167

ON

ON

ON

OFF

OFF

ON

OFF

ON

168

OFF

OFF

OFF

ON

OFF

ON

OFF

ON

 

 

 

 

 

 

 

 

 

(Continued on next page)

Pelco Manual C1498M-B (7/99)

7

Image 7
Contents Listed Contents Models Important Safeguards and WarningsInstallation DescriptionTable B. Switch Settings for SW2 P-Type Control Table C. Switch Settings for SW2 D-Type Control OFF 113 169 Operation POWER-UP DisplayScan Speed Preset FunctionsPAN and Tilt Functions Auto FlipPark Main Menu AccessProgramming the Spectra Lite CM9760 Reset CameraBacklight Compensation CM9750Auto Iris GAIN/AGCShutter Speed AUTO-FOCUS ModeWhite Balance SharpnessLine Synchronization POWER-UP Mode Park Time Minutes Limit StopsSymptom Unit or fan does not operate TroubleshootingBack BOX Electronic Assembly Removal SpecificationsRegulatory Notices Warranty and Return Information