Coleman F*FP installation manual Series

Page 15

292043-UIM-B-0707

F* SERIES

Air Handler Control Wiring

Typical A/C - Cooling only Applications

THERMOSTAT

AIR HANDLER

1 - STAGE

 

 

BOARD

 

 

 

 

 

AIR CONDITIONING

 

R

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

Y

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W1

 

 

W1

 

 

 

HUMIDISTAT 1

W2

 

 

W2

 

 

 

 

 

 

 

 

 

 

CO

C C

CFM selection

HUM

 

 

1 NOTE:

 

X

board only on

 

Dehumidification

F4FV model

Y1

control connection

 

 

 

 

Y2

(”Humidistat” jumper on

 

 

CFM selection board

 

 

 

 

 

 

 

 

 

must be removed)

F* SERIES

Air Handler Control Wiring

Typical A/C with Electric Heat Applications

THERMOSTAT

AIR HANDLER

1 - STAGE

 

 

BOARD

 

 

 

 

 

AIR CONDITIONING

 

R

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

Y

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

G

 

Field

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W1

 

 

W1

 

HUMIDISTAT

1

 

 

 

Installed

 

 

 

 

 

 

 

 

 

W2

 

 

W2

 

Jumper -

 

 

 

 

 

 

 

 

 

If Required

 

 

 

 

 

 

 

 

 

 

CO

C C

CFM selection

HUM

 

 

1 NOTE:

 

X

board only on

 

Dehumidification

F4FV model

Y1

control connection

 

 

 

 

Y2

(”Humidistat” jumper on

 

 

CFM selection board

 

 

 

 

 

 

 

 

 

must be removed)

FIGURE 12: Cooling Models with Electric Heat Wiring

 

 

 

AIR HANDLER

HEAT PUMP

THERMOSTAT

 

BOARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

R

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

Y

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

W1

 

 

W1 Out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W2

 

 

W2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

O

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

C

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

X/L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W1

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM selection board only on F4FV model

HUM

X

Y1

Y2

HUMIDISTAT 1

1NOTE:

Dehumidification control connection (”Humidistat” jumper on CFM selection board must be removed)

FIGURE 13: Single Stage Heat Pump Control Wiring

NOTES:

1.“Y” Terminal on Air Handler Control Board must be connected for full CFM and applications requiring 60 second Blower Off Delay for SEER enhancement.

2.1Optional Dehumidification Humidistat contacts open on rise.

3.For F4FV model - Remove Humidistat Jumper on CFM Selection Board - if used.

4.For F4FV model - For Heat Pump Applications - Remove Heat Pump Jumper on CFM Selection Board.

5.To change quantity of heat during HP defrost cycle - Reverse connections at W1 and W2 on Air Handler Control Board.

Unitary Products Group

15

Image 15
Contents Installation Manual Inspection Specific Safety Rules and PrecautionsSafety Requirements General InformationHorizontal Drain PAN Conversion Models F*FP Coil Metering Devices Duct ConnectionsAIR Filters Suspension KitsRefrigerant Line Connection UIM-B-0707 Unitary Products Group Line Power Connections LOW Voltage Control ConnectionBlower Speed Connections 048 060 KW & MBH Conversions for Total Power Input RequirementModels F*FP 036 040Max. Static Total Heat2 Min. CFMW1 Only W2 Only W1 + W2 Model 75C Wire Size AWGMin. Circuit Ampacity Heater208V 240V Max. Static Total HeatW1 Only Static Tap 208 240590 502 400 F4FP024H06T2 Med 845 815 Airflow Data for 230 Volt Heat Pump Models1High 950 910 835 775 730Blower Motor Volt Series Drain Connections MaintenanceCoil Cleaning Troubleshooting Guide

F*FP specifications

The Coleman F*FP, an innovative product from the renowned outdoor gear manufacturer Coleman, represents a significant leap forward in portable lighting solutions. Designed for outdoor enthusiasts, campers, and emergency preparedness, this compact device merges functionality with cutting-edge technology.

One of the standout features of the Coleman F*FP is its impressive brightness, which can easily illuminate small campsites or provide adequate light for activities such as cooking or reading after sunset. With adjustable brightness settings, users can customize the light output according to their specific needs, effectively conserving battery life when full brightness isn’t necessary.

The Coleman F*FP incorporates advanced LED technology, ensuring longevity and efficiency. Unlike traditional incandescent bulbs, the LEDs offer a much longer lifespan and consume significantly less power, making them an ideal choice for outdoor use where access to electricity may be limited. This energy-efficient design makes the F*FP not only cost-effective but also environmentally friendly.

Portability is another key characteristic of the Coleman F*FP. The device is lightweight and compact, making it easy to pack and transport, whether you're heading on a weekend camping trip or preparing for an emergency situation. It typically features a built-in handle or a hook for easy hanging, allowing for versatile placement in tents, trees, or outdoor structures.

Durability is paramount when it comes to outdoor equipment, and the Coleman F*FP does not disappoint. Constructed with weather-resistant materials, it can withstand various environmental conditions, from rain to dust, ensuring reliable performance and longevity. This rugged construction makes it a trustworthy companion for any outdoor adventure.

The F*FP also includes user-friendly features such as easy-to-navigate controls and battery indicators. Some models may offer rechargeable options, reducing the need for disposable batteries and enhancing sustainability.

In summary, the Coleman F*FP stands out in the realm of outdoor lighting solutions. Its impressive brightness, energy-efficient LED technology, portability, and durable construction make it an essential tool for adventurers and a sensible choice for emergency preparedness. With the Coleman F*FP in tow, users can enjoy peace of mind and a well-lit experience in the great outdoors.