MAINTENANCE

LUBRICATION

B

A

A

Fig. 36

The variable speed pulleys and the speed range shifter mechanism should be oiled weekly with a few drops of light machine oil in the two oil holes (A) Fig. 38, located on top of the variable speed pulleys and the hole (B) located on top of the shifter mechanism.

IMPORTANT: Oil the holes when the drill press is turned OFF. Then turn the machine ON and run through the low and high speed ranges a few times.

18

Image 18
Contents 16½ Variable Speed Drill Press Safety Guidelines Definitions Additional Safety Rules for Drill Presses Refer to them often Use them to instruct othersPower Connections Unpacking and Cleaning Extension CordsDrill Press Parts 11A 11B12Assembly With 3mm Wrench Supplied Page For Model 17-925 only For Model 17-990X onlyPage Fastening Drill Press Base to a Supporting Surface Permanent MountingMounting Drill Press to a Plywood Base Table Adjustments Operating Controls and AdjustmentsLocking Switch OFF Position Starting and Stopping Drill PressVariable Speed Control Speed Range ControlDrilling Holes to Depth Quill Adjustments Adjusting Spindle Return SpringInstalling and Removing Drill Bits OperationsCorrect Drilling Speeds Boring in Wood Drilling MetalMaintenance LubricationAccessories PARTS, Service or Warranty AssistanceCanadian PORTER-CABLE Delta Service Centers