GLOSSARY

Become familiar with these terms before operating the unit. CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure of air delivery.

PSIG: Pounds per square inch gauge; a unit of measure of pressure.

ASME: American Society of Mechanical Engineers; made, tested, inspected and registered to meet the standards of the ASME.

Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety labo- ratories and meet the applicable Underwriters Laboratories Standards for Safety.

Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to the factory set low pressure the motor will restart automatically. The low pressure at which the motor automati- cally restarts is called “cut-in” pressure.

Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a factory set high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called “cut-out” pressure.

Branch Circuit: Circuit carrying electricity from electrical panel to outlet.

SPECIFICATIONS

 

 

Model No.

CPLC7060V

 

 

Horsepower Peak

7.0

 

 

Voltage/Hertz/Phase

240V/60/1

 

 

Minimum Branch Circuit Requirement

15 Amp

*

Fuse Type

Time Delay

 

 

Air Tank Capacity (Gallon)

60 ASME, Vertical

 

 

Approximate Cut-in Pressure

110 PSIG

 

 

Approximate Cut-out Pressure

135 PSIG

 

 

SCFM @ 40 PSIG

12.1

 

 

SCFM @ 90 PSIG

9.7

*

 

 

 

 

This air compressor can be operated on a 15 amp circuit if:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Voltage supply to circuit is normal.

2.Circuit is not used to supply any other electrical needs (lights, appliances, etc.)

3.Extension cords comply with specifications in owners manual.

4.Circuit is equipped with 15 amp circuit breaker or 15 amp time delay fuse marked Type D.

If any of the above conditions cannot be met, or if operation of the air compressor repeatedly causes interruption of the power it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit on which the air compressor is operated. If the air com- pressor is connected to a circuit protected by fuses, use dual element time delay fuses.

ACCESSORIES

Accessories for this unit are available at the store the unit was purchased.

D23269

6 - ENG

Image 6
Contents Instruction Single Stage Oillube Manual Compressor Safety Guidelines Definitions Important Safety InstructionsRead and Follow ALL Instructions Hazard Risk of Explosion or Fire What can Happen HOW to Prevent ITWhat can Happen HOW to Prevent IT Risk of BurstingRisk from Flying Objects What can Happen HOW to Prevent IT Risk to Breathing What can Happen HOW to Prevent ITRisk of Electrical Shock What can Happen HOW to Prevent IT Risk of Falling What can Happen HOW to Prevent IT Risk from Moving Parts What can Happen HOW to Prevent ITRisk of Burns What can Happen HOW to Prevent IT Risk of Property Damage When Transporting CompressorGlossary SpecificationsAccessories CPLC7060VUnpacking AssemblyTools Required for Assembly To Add Oil To PumpInstallation Location of the Air CompressorAnchoring of the Air Compressor Wiring Instructions Voltage and Circuit ProtectionAir Distribution System Operation Know Your Air Compressor Description of OperationHow to Stop Break-in ProcedureMaintenance To Check Safety ValveCustomer Responsibilities Air Filter Inspection and Replacement To Drain TankOil Motor Pulley/Flywheel Alignment Air Compressor Pump Intake and Exhaust ValvesInspect Air Lines and Fittings for Leaks Service and Adjustments To Replace or Clean Check ValveMotor To Replace BeltStorage Troubleshooting Problem Cause CorrectionWith the filter removed. Refer to Problem Cause Correction Problem Cause Correction ENG D23269 Limited Warranty This Warranty is not Transferable and does not Cover