Page 12
Pressure Release Valve

Drain Valve: The

 

 

drain valve is located

Drain

at the base of the air

Valve

tank and is used to

 

drain condensation at

 

the end of each use.

 

Check Valve: When the air

compressor is

 

 

 

operating, the

 

 

 

check valve

 

 

 

is "open",

 

 

 

allowing

 

 

 

compressed

 

 

 

air to enter

 

Check Valve

the air tank.

 

 

 

 

When the

 

 

air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank.

Pressure Release Valve: The pressure release

valve located on the side of the pressure switch, is designed to automatically release compressed air from the compressor head

and the outlet tube when the air compressor reaches "cut-out" pressure or is shut Off. The pressure release valve allows the motor to restart freely. When the motor stops running, air will be heard escaping from this valve for a few seconds. No air should be heard leaking when the motor is running

or after the unit reaches "cut-out" pressure.

Motor Overload Protector (not shown): The motor has an automatic reset thermal overload protector. If the motor overheats for any reason, the overload protector will shut

Off the motor. The motor must be allowed to cool down before restarting. The compressor will automatically restart after the motor cools.

Air Intake Filter (not shown): This filter is designed to clean air coming into the pump. This filter must always be clean and ventilation openings free from obstructions. See "Maintenance".

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off lever to "Off".

Before First Start Up

Risk of Unsafe Operation. Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "Off" position.

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Open the drain valve (counter- clockwise) fully to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

4.Move the On/Auto/Off lever to "On/Auto" position. The compressor will start.

5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve by turning clockwise. The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

A09770

12 - ENG

Image 12
Contents Pancake Compressor Safety Guidelines Definitions Important Safety InstructionsOr serious injury Or moderate injury Death or serious injuryHow To Prevent It What Could HappenAlways remain in attendance with Attachments & Accessories Electricity. Like any other electrically Repairs attempted by unqualifiedOr death Conjunction with the compressor must beResult in serious burns How To Prevent It Hazard Warning Risk from Moving PartsNever defeat the safety features of this Keep children away from the air compressor at all timesEquip area of operation with a fire extinguisher Specifications AccessoriesGlossary Duty Cycle Assembly Installation Unpacking Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionOperation Know Your Air CompressorDescription of Operation Check Valve When the air How to StopBefore First Start Up Drain ValveMaintenance How to StartBefore Each Start-Up Customer ResponsibilitiesTo Check Safety Valve Air Filter Inspection ReplacementTo Drain Tank Air Compressor Pump Intake and Exhaust ValvesService and Adjustments To Replace or Clean Check ValveTo Replace Regulator Storage Troubleshooting Being used Check wiring connection ENG A09770 Limited Warranty