Porter-Cable 345 instruction manual Replacement Parts, Motor, Extension Cord Selection

Page 6

3

 

 

 

........................

three-phase alternating current

3N

three-phase alternating current with neutral

 

 

 

 

........................

direct current

n0

no load

 

 

 

 

........................

alternating or direct current

 

 

 

 

 

Class II Construction

 

 

 

 

 

 

 

 

 

........................

 

 

 

 

 

 

 

 

 

........................

splash-proof construction

 

 

 

 

........................

watertight construction

…/min

revolutions or reciprocation per minute

REPLACEMENT PARTS

When servicing use only identical replacement parts.

MOTOR

Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60 cycle A.C. current and voltage within plus or minus 5 percent of that shown on the specification plate on the tool. Several models, however, are designed for A.C. current only. Refer to the specification plate on your tool for proper voltage and current rating.

CAUTION: Do not operate your tool on a current on which the voltage is not within correct limits. Do not operate tools rated A.C. only on D.C. current. To do so may seriously damage the tool.

EXTENSION CORD SELECTION

If an extension cord is used, make sure the conductor size is large enough to prevent excessive voltage drop which will cause loss of power and possible motor damage. A table of recommended extension cord sizes will be found below. This table is based on limiting line voltage drop to 5 volts (10 volts for 230 volts) at 150% of rated amperes.

If an extension cord is to be used outdoors it must be marked with the suffix W-A or W following the cord type designation. For example – SJTW-A to indicate it is acceptable for outdoor use.

RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS

Length of Cord in Feet

 

115V

25 Ft.

50 Ft.

100 Ft.

150 Ft.

200 Ft.

250 Ft.

300 Ft.

400 Ft.

500 Ft.

 

230V

50 Ft.

100 Ft.

200 Ft.

300 Ft.

400 Ft.

500 Ft.

600 Ft.

800 Ft.

1000 Ft.

 

 

 

 

 

 

 

 

 

 

 

 

0-2

18

18

18

16

16

14

14

12

12

 

 

 

 

 

 

 

 

 

 

 

Rating

2-3

18

18

16

14

14

12

12

10

10

 

 

 

 

 

 

 

 

 

 

3-4

18

18

16

14

12

12

10

10

8

4-5

18

18

14

12

12

10

10

8

8

Ampere

 

 

 

 

 

 

 

 

 

 

5-6

18

16

14

12

10

10

8

8

6

 

 

 

 

 

 

 

 

 

 

6-8

18

16

12

10

10

8

6

6

6

8-10

18

14

12

10

8

8

6

6

4

Nameplate

 

 

 

 

 

 

 

 

 

 

10-12

16

14

10

8

8

6

6

4

4

 

 

 

 

 

 

 

 

 

 

12-14

16

12

10

8

6

6

6

4

2

14-16

16

12

10

8

6

6

4

4

2

 

 

 

 

 

 

 

 

 

 

 

16-18

14

12

8

8

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

 

 

18-20

14

12

8

6

6

4

4

2

2

6

Image 6 Contents
SAW Boss Personal Safety General Safety RulesElectrical Safety Work AreaService Tools USE and CareSpecific Safety Rules and Symbols Symbol Definition Replacement Parts MotorExtension Cord Selection Foreword Installing the BladeFunctional Description Selecting a BladeTelescoping Guard To Adjust Depth of CUT for Normal Cutting To Adjust for Bevel Cuts To Adjust 90 Positive StopTo Adjust 45 Bevel Positive Stop Line of CUT Indicator To Assemble the Optional Base InsertInstalling Sawdust Exhaust Nozzle Installing and Care of Dust BAGVacuum Cleaner Adapter HOW to USE the SAW To Assemble RIP GuideCROSS-CUTTING RippingBevel Cutting Pocket Cuts Plunge Cutting Maintenance Accessories PORTER-CABLE Limited ONE Year WarrantyCanadian PORTER-CABLE Delta Service Centers
Related manuals
Manual 17 pages 9.79 Kb