Bryant installation instructions Base Unit Dimensions Ð 564A/764A024-036, Ð2Ð

Page 2

UNIT

ELECTRICAL

UNIT

CENTER OF GRAVITY mm [in.]

WEIGHT

564A/764A

CHARACTERISTICS

 

 

 

 

 

Lb

Kg

X

Y

Z

 

 

024

208/230-1-60

222

101

355.6 [14.00]

508.0 [20.00]

241.3 [9.50]

030

208/230-1-60

236

107

355.6 [14.00]

508.0 [20.00]

241.3 [9.50]

036

208/230-1-60, 208/230-3-60

250

114

355.6 [14.00]

508.0 [20.00]

241.3 [9.50]

 

 

 

 

 

 

 

LEGEND

NEC Ð National Electrical Code

REQUIRED CLEARANCES TO COMBUSTIBLE MATERIAL, mm [in.]

Top of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0

Duct Side of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . 0

Side Opposite Ducts . . . . . . . . . . . . . . . . . . . . . . . . 0

Bottom of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0

NEC REQUIRED CLEARANCES, mm [in.]

 

Between Units, Power Entry Side . . .

. . . . 1066.8

[42.00]

Unit and Ungrounded Surfaces,

 

 

Power Entry Side

. . . . 914.0

[36.00]

Unit and Block or Concrete Walls and Other

 

Grounded Surfaces, Power Entry Side

. . . . 1066.8 [42.00]

REQUIRED CLEARANCES FOR SERVICING, mm [in.]

Condenser Coil Access Side . . . . . . . . . . . . 762.0 [30.00]

Power Entry Side

(Except for NEC Requirements) . . . . . . . . . 762.0 [30.00]

Unit Top . . . . . . . . . . . . . . . . . . . . . . . . 914.0 [36.00]

Side Opposite Ducts . . . . . . . . . . . . . . . . . 762.0 [30.00]

NOTES:

1.Clearances must be maintained to prevent recirculation of air from condenser-fan discharge. With the exception of the condenser coil (914 mm [36 in.]), a removable fence or bar- ricade requires no clearance.

2. Dimensions are in millimeters. Dimensions in [ ] are in inches.

Fig. 2 Ð Base Unit Dimensions Ð 564A/764A024-036

Ð2Ð

Image 2
Contents Safety Considerations Important Ð Read Before InstallingContents InstallationBase Unit Dimensions Ð 564A/764A024-036 Ð2ÐBase Unit Dimensions Ð 564A/764A042,048 Ð3ÐBase Unit Dimensions Ð 564A/764A060 Ð4ÐClearance Ground-Level InstallationLocate the Unit II. RIG and Place UnitÐ6Ð Physical DataField-Duct Connections Shipping Location of Duct Flanges Size 060 Only Ð7ÐÐ8Ð Do not USE Aluminum WireElectrical Connections Control Box Wiring Unit Electrical Connection Entry HolesElectrical Data FLA MCA Mocp LRAAccessory Installation PRE-START-UPSTART-UP Heating Section START-UP and Adjustments II. Cooling Section START-UP and AdjustmentsIII. Indoor Airflow and Airflow Adjustments II. Evaporator FAN and Motor Care and MaintenanceAIR Filter Unit Top Removal Service CleaningRepairing Refrigerant Leaks Condenser Coil, Evaporator Coil, and Condensate Drain PanIndoor Airflow IV. Electrical Controls and WiringIX. Replacement Parts VI. Metering Device ServicingCooling Charging Chart Ð 564A/764A024 Cooling Charging Chart Ð 564A/764A048 Cooling Troubleshooting Chart Symptom Cause RemedyPage Page Packaged Service Training Page Preliminary Information START-UP ChecklistTemperatures III. START-UP Electrical

764A specifications

The Bryant 764A is a high-performance air conditioning and heating system that exemplifies efficiency and reliability for residential and commercial use. Designed to deliver optimal comfort in various climates, the 764A is known for its impressive energy efficiency ratings and advanced technologies.

One of the standout features of the Bryant 764A is its variable speed compressor. This innovative component allows the system to adjust its output according to the specific cooling or heating demands of the environment. By operating at different speeds, the compressor can maintain a consistent indoor temperature while using less energy compared to traditional single-stage systems. This not only enhances comfort but also contributes to significant energy savings over time.

The Bryant 764A is equipped with a smart thermostat that offers precise control over indoor climates. This thermostat can be programmed to adjust temperatures based on user preferences and schedules, further improving energy efficiency. Users can also control the system remotely via a smartphone app, ensuring comfort is just a tap away.

In terms of its construction, the Bryant 764A is built with durability in mind. The unit features a robust cabinet designed to withstand harsh weather conditions, which extends the lifespan of the system. Additionally, its sound-dampening technology minimizes operational noise, creating a more peaceful indoor environment.

The 764A incorporates advanced filtration systems to improve indoor air quality. With allergen filtration capabilities, it effectively reduces dust, pollen, and other airborne particles, making it an excellent choice for allergy sufferers. This focus on air quality aligns with Bryant's commitment to creating healthier living spaces.

Moreover, the Bryant 764A is designed with environmentally friendly refrigerants, aligning with modern standards for reducing greenhouse gas emissions. This commitment to sustainability is becoming increasingly important for consumers looking to reduce their environmental footprint.

Overall, the Bryant 764A stands out as a comprehensive solution for heating and cooling needs. With its variable speed technology, smart thermostat, durable construction, and focus on air quality, it offers both efficiency and comfort, making it a wise investment for any property owner looking to enhance their indoor environment.