Master

With the Port 01 FX as the Master, press the <PORT> soft key to change the remaining Ports and designate the remaining FXs as Slaves. The MATE screen for Port 02 will look like this:

ADV/FX/STACK

--------P02

stack

Master

phase

 

DOWN INC

DEC PORT

ADV/FX/STACK

---------P02

stack

Master

phase

 

DOWN INC DEC PORT

The MATE is now ready to program the FX plugged into Port 02 of the HUB.

Master is the factory default value for each grid-inter- active FX.

Pressing the <INC> soft key will keep the MATE’s attention on Port 02, but will change the stack phase to Classic Slave screen. Port 02 will then be assigned as a Classic slave. You can change the stacking phase by pressing the <INC> or <DEC> soft keys and change to a different port by continuously pushing the <PORT> soft key.

Note: There are no <OK> or <DONE> commands in the stacking menu. Whichever value—Master or Slave—shows up on the MATE screen will be assigned to the chosen Port (and FX) upon leaving that screen. It’s important to watch the Port number in the top right corner of each screen to be sure you’ve assigned it the desired status.

CLASSIC Slave

ADV/FX/STACK---------

P02

stack

Classic

Slave

phase

 

• PO2 is now assigned as a Classic Slave.

DOWN

INC DEC

PORT

13

Image 14
Contents Grid-Interactive Disclaimer Warranty SummaryAbout Outback Power Systems Contact InformationTable of Contents Condition Voltage Range VAC Frequency Hz Seconds Allowed Important Safety Instructions Stacking Options Grid-INTERACTIVE FX Series Inverter/Charger ProgrammingStacking Concerns Components and Connections LED Color LED Action LED Indicates Mate Screens Stacking and Assigning FX Status Stacking OptionsClassic Stacking MasterProgramming the FXs 141ADV Down INC DEC Master Classic SlavePower Save Levels AC on Turn the AC input breakers on Auxiliary AUX Functions ADV/PASSWORD P00 Adjustable AUX Output Functions List of AUX FunctionsP00 ADV/FX/AUX Battery Charging Setpoints Battery Charging InstructionsMaintenance FX Default Values subject to change with FX upgrades GenAlert Off Set Point On Set PointWarranty OutBack Power Systems Two Year Limited WarrantyExtended Warranty Application U.S. and Canada only Product RegistrationYear Limited Warranty California GTFX, Gvfx and PS1 ProductsRevision.2007-06-01 System Owner Year Warranty Registration CaliforniaInstaller Product