Multiquip GB2000 manual Lamp adapter Plate mounting Installation

Page 24

type 2 setup (S/N G1900119 and above)

Lamp adapter Plate mounting Installation

1.Remove the adapter plate kit hardware from its container.

2.Before proceeding make sure the light tower mast is in the stow position (down) and the cradle lock/release pin has been inserted and the mast is locked.

3.Attach the lamp adapter plate to the T-Bar as shown in Figure 18. Align adapter plate so that adapter spacer notch fits over screw on T-Bar. Please pay close attention to the orientation of the 2 support brackets.

4.Mount the flat end of both support brackets flush against the T-Bar with the low end of each bracket facing inward toward the mast.The raised end of each bracket should be facing outward.

NOTICE

Please pay close attention to the orientation of the 2 support brackets. Each bracket has a high and low side. the low side of the bracket should be facing inwards towards the mast.

5.Next, insert a bolt (4) and flat washer (4) thru the mounting holes on the the adapter plate as shown in Figure 18. Again, pay close attention on which set of holes to insert the bolt thru. Bolt number 2 must be oriented so that it passes between receptacles J1 and J2 on the T-Bar.

6.Secure the adapter plate to the T-Bar using the supplied flat washer (4), lock washer (4) and nut (4). Make sure the adapter plate is level (use a bubble level) and both brackets are straight (vertical), not slanted before tightening

page 24 —gb2000 balloon light• operation and parts manual — rev. #3 (08/30/12)

Image 24
Contents Model GB2000 Proposition 65 warning Table of Contents GB2000 Balloon LightChoose from three easy options Safety information SaFeTy messagesGeneral saFeTy LighT ToWer saFeTy Lamp saFeTyEngine saFeTy  The engine of this equipment Requires an adequate freeFuel saFeTy ToWing saFeTy lighT ToWerTransporTing saFeTy  never lift the equipment while engine is runningEleCTriCal saFeTy Power Cord/Cable safetyGrounding safety BaTTery saFeTy EnvironmenTal saFeTySpecifications SpecificationsDimensions Type 1 AdapterFootcandle plot Footcandle PlotGeneral Information Page Type 1 Components S/N g1900118 and below GB2000 Components Type 1 S/N G1900118 And BelowType 2 Components S/N g1900119 and above GB2000 Components Type 2 S/N G190019 And AboveType 1 setup S/N G1900118 and below DisassemblyPReparation Assembly Lamp RemovalFan/Balloon Power cable Connection PIN Lamp Power cable ConnectionLamp cable connections lt12 Lamp cable Connections MLTType 2 setup S/N G1900119 and above Power DisconnectionLamp adapter Plate mounting Installation Remove the adapter plate kit hardware from its containerLock Washer HEX NUT Fan power cable connection Balloon Power cableJunction box mounting Lamp mountingRear Front Lamp lighting options Lamp Cable connectionsGB2000 Lamp Lamp Lamp Option 6 Lighting Configuration Operation Removing balloOn protective coverInflating Balloon and Turning on LAMPs LT12 only Inflating Balloon and Turning on LAMPs mlt only Deflating and storing balloonMaintenance Replacing LampReplacing Balloon Symptom Possible Problem Solution Wiring diagram Explanation of Code in Remarks Column Suggested Spare Parts Gb2000 bALLOON Light 1 to 3 unitsElectrical assy Part Name QTY Remarks Electrical assy Plate CAP Bracket and J-BOX assy. S/N G1900118 and below Junction BOX Relay Bracket and J-BOX assy. S/N G1900119 and Above Screw & Washer M3 X Terms and Conditions of Sale Parts FreighT poliCyPage HERE’S HOW to GET Help
Related manuals
Manual 48 pages 36.64 Kb

GB2000 specifications

The Multiquip GB2000 is a cutting-edge generator designed to meet the needs of a variety of industries, offering reliable and efficient power solutions. Built with advanced technology and user-friendly features, the GB2000 is tailored for both professionals and contractors who require consistent performance in demanding environments.

One of the standout characteristics of the GB2000 is its robust engine, which is engineered for high efficiency and low emissions. This generator is powered by a high-performance engine that provides a substantial power output, ensuring that it can support a wide range of devices and tools. The emphasis on performance makes it suitable for construction sites, events, and emergency backup applications.

The GB2000 also boasts a compact and durable design, making it easy to transport and store. Its lightweight frame does not compromise on durability, as it is built from high-quality materials that can withstand the rigors of daily use. This portability is enhanced by built-in handles and a well-balanced structure, allowing users to maneuver it effortlessly in various settings.

Another significant feature of the GB2000 is its digital control panel, which provides real-time information about power output, fuel levels, and operational status. This intuitive control interface simplifies operation and enhances user experience, allowing users to monitor their power needs effectively and make quick adjustments as necessary.

In terms of safety, the Multiquip GB2000 incorporates several protective measures. This includes automatic low oil shutdown, circuit breaker protection, and a robust frame that protects the engine from external impacts. These features ensure the longevity of the generator while also providing peace of mind to users in high-demand situations.

Technologically, the GB2000 utilizes an advanced inverter system that delivers clean and stable power, crucial for sensitive electronic devices. This inverter technology not only improves fuel efficiency but also minimizes noise production, making it ideal for use in environments where sound levels are a concern.

Overall, the Multiquip GB2000 combines power, portability, and advanced technology, making it a top contender in the portable generator market. Its user-friendly design, safety features, and robust performance ensure it meets the diverse requirements of modern power users, establishing it as a reliable choice for both everyday and emergency power needs.