Multiquip GB2000 manual Maintenance, Replacing Lamp

Page 36

maintenance

REPLACING LAMP

DANGER

Never attempt to replace lamp in a wet place. The possibility exists of electric shock.

WARNING

Always allow sufficient time for the lamp to cool down before replacing.The possibility exists of severe burns if hot lamp is touched.

\ CAUTION

Always shutdown power source and remove balloon assembly from mast when replacing a broken lamp. Utmost care should be taken in handling broken lamp. The possibility exists of serious injury from handling a broken lamp.

1.Unzip the zipper at the bottom of the balloon and roll the balloon up to expose the lamp. See Figure 33.

BALLOON

ZIPPER

Figure 33. Exposing Balloon

2.Release the lamp guard hooks from the poles and remove the two lamp guards. See Figure 34.

LAMP GUARD

LOCK HOOK

Figure 34. Removing Lamp Guard

3.Press the tabs on the lamp holder and push up lamp holder to release it from lamp. Do the same to the lower lamp if necessary. See Figure 35.

LAMP HOLDER

LAMP

HOLDER

STOPPER

Figure 35. Lamp Holder

4.Remove lamp from the lamp socket by turning lamp counterclockwise. See Figure 36.

LAMP

LAMP

SOCKET

Figure 36. Removing Lamp

5.Install new lamp into socket and turn lamp in a clockwise direction until tight. See Figure 37.

LAMP

LAMP

SOCKET

Figure 37. Installing New Lamp

page 36 —gb2000 balloon light• operation and parts manual — rev. #3 (08/30/12)

Image 36
Contents Model GB2000 Proposition 65 warning Table of Contents GB2000 Balloon LightChoose from three easy options Safety information SaFeTy messagesGeneral saFeTy LighT ToWer saFeTy Lamp saFeTyEngine saFeTy  The engine of this equipment Requires an adequate freeFuel saFeTy ToWing saFeTy lighT ToWerTransporTing saFeTy  never lift the equipment while engine is runningEleCTriCal saFeTy Power Cord/Cable safetyGrounding safety BaTTery saFeTy EnvironmenTal saFeTySpecifications SpecificationsDimensions Type 1 AdapterFootcandle plot Footcandle PlotGeneral Information Page Type 1 Components S/N g1900118 and below GB2000 Components Type 1 S/N G1900118 And BelowType 2 Components S/N g1900119 and above GB2000 Components Type 2 S/N G190019 And AboveType 1 setup S/N G1900118 and below DisassemblyPReparation Assembly Lamp RemovalFan/Balloon Power cable Connection PIN Lamp Power cable ConnectionLamp cable connections lt12 Lamp cable Connections MLTType 2 setup S/N G1900119 and above Power DisconnectionLamp adapter Plate mounting Installation Remove the adapter plate kit hardware from its containerLock Washer HEX NUT Fan power cable connection Balloon Power cableJunction box mounting Lamp mountingRear Front Lamp lighting options Lamp Cable connectionsGB2000 Lamp Lamp Lamp Option 6 Lighting Configuration Operation Removing balloOn protective coverInflating Balloon and Turning on LAMPs LT12 only Inflating Balloon and Turning on LAMPs mlt only Deflating and storing balloonMaintenance Replacing LampReplacing Balloon Symptom Possible Problem Solution Wiring diagram Explanation of Code in Remarks Column Suggested Spare Parts Gb2000 bALLOON Light 1 to 3 unitsElectrical assy Part Name QTY Remarks Electrical assy Plate CAP Bracket and J-BOX assy. S/N G1900118 and below Junction BOX Relay Bracket and J-BOX assy. S/N G1900119 and Above Screw & Washer M3 X Terms and Conditions of Sale Parts FreighT poliCyPage HERE’S HOW to GET Help
Related manuals
Manual 48 pages 36.64 Kb

GB2000 specifications

The Multiquip GB2000 is a cutting-edge generator designed to meet the needs of a variety of industries, offering reliable and efficient power solutions. Built with advanced technology and user-friendly features, the GB2000 is tailored for both professionals and contractors who require consistent performance in demanding environments.

One of the standout characteristics of the GB2000 is its robust engine, which is engineered for high efficiency and low emissions. This generator is powered by a high-performance engine that provides a substantial power output, ensuring that it can support a wide range of devices and tools. The emphasis on performance makes it suitable for construction sites, events, and emergency backup applications.

The GB2000 also boasts a compact and durable design, making it easy to transport and store. Its lightweight frame does not compromise on durability, as it is built from high-quality materials that can withstand the rigors of daily use. This portability is enhanced by built-in handles and a well-balanced structure, allowing users to maneuver it effortlessly in various settings.

Another significant feature of the GB2000 is its digital control panel, which provides real-time information about power output, fuel levels, and operational status. This intuitive control interface simplifies operation and enhances user experience, allowing users to monitor their power needs effectively and make quick adjustments as necessary.

In terms of safety, the Multiquip GB2000 incorporates several protective measures. This includes automatic low oil shutdown, circuit breaker protection, and a robust frame that protects the engine from external impacts. These features ensure the longevity of the generator while also providing peace of mind to users in high-demand situations.

Technologically, the GB2000 utilizes an advanced inverter system that delivers clean and stable power, crucial for sensitive electronic devices. This inverter technology not only improves fuel efficiency but also minimizes noise production, making it ideal for use in environments where sound levels are a concern.

Overall, the Multiquip GB2000 combines power, portability, and advanced technology, making it a top contender in the portable generator market. Its user-friendly design, safety features, and robust performance ensure it meets the diverse requirements of modern power users, establishing it as a reliable choice for both everyday and emergency power needs.