Bryant 702B, 602B installation instructions ±583B & 683B COOLING AND HEAT PUMP HEATING-683B ONLY

Page 24

TABLE 11±583B & 683B COOLING (AND HEAT PUMP HEATING-683B ONLY)

DRY COIL ICM AIRFLOW

SMALL CABINET

 

 

CFM ADJUST

 

LO PIN

 

 

 

NOM PIN

 

 

HI PIN

 

UNIT

 

PIN SELECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIZE

 

EXTERNAL STATIC

0.0±0.4

0.4±0.7

0.7±1.0

 

0.0±0.4

0.4±0.7

0.7±1.0

0.0±0.4

0.4±0.7

0.7±1.0

 

 

PRESSURE RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING ²

745

675

±

 

835

750

690

940

880

815

024

 

COOLING

675

625

±

 

675

650

600

755

730

705

 

DEHUMIDIFY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT PUMP

670

605

±

 

740

690

635

845

795

735

 

COMFORT (683B Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING ²

940

860

785

 

1020

965

895

1185

1100

1010

030

 

COOLING

820

785

735

 

820

800

770

955

920

880

 

DEHUMIDIFY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT PUMP

850

780

745

 

935

905

845

1055

1040

955

 

COMFORT (683B Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING ²

1025

935

±

 

1145

1085

1005

1320

1260

1180

036

 

COOLING

925

885

±

 

925

900

870

1060

1040

1010

 

DEHUMIDIFY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT PUMP

955

880

±

 

1075

990

920

1220

1180

1125

 

COMFORT (683B Only)

 

 

 

 

 

 

 

 

 

 

 

 

² On 683B Only

Heat Pump Efficiency and Cooling pin selections deliver equal airflow

 

 

 

 

 

 

TABLE 12Ð583B & 683B COOLING (AND HEAT PUMP HEATING-683B ONLY)

DRY COIL ICM AIRFLOW

LARGE CABINET

 

CFM ADJUST

LO PIN

NOM PIN

HI PIN

UNIT

PIN SELECT

 

 

 

SIZE

EXTERNAL STATIC

0.1±1.0

0.1±1.0

0.1±1.0

 

PRESSURE RANGE

 

 

 

 

 

COOLING ²

1100

1225

1410

 

 

 

 

 

042

COOLING

980

980

1125

DEHUMIDIFY

 

 

 

 

HEAT PUMP

990

1100

1265

 

COMFORT (683B Only)

 

 

 

 

 

COOLING ²

1260

1400

1610

 

 

 

 

 

048

COOLING

1120

1120

1290

DEHUMIDIFY

 

 

 

 

HEAT PUMP

1135

1260

1450

 

COMFORT (683B Only)

 

 

 

 

 

COOLING ²

1575

1750

2010

 

 

 

 

 

060

COOLING

1400

1400

1610

DEHUMIDIFY

 

 

 

 

HEAT PUMP

1415

1575

1810

 

COMFORT (683B Only)

 

 

 

 

 

 

 

 

 

² On 683B Only

Heat Pump Efficiency and Cooling pin selections deliver equal airflow

 

 

TABLE 13Ð583B & 683B GAS HEATING ICM AIRFLOW

SMALL CABINET

EASY SELECT™

 

700

 

 

800

 

 

1100

 

 

1250

 

BOARD SETTING (CFM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External

 

 

 

 

 

 

 

 

 

 

 

 

Unit

Static

0.0±0.4

0.4±0.7

0.7±1.0

0.0±0.4

0.4±0.7

0.7±1.0

0.0±0.4

0.4±0.7

0.7±1.0

0.0±0.4

0.4±0.7

0.7±1.0

Size

Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Heat Size

 

 

 

 

 

 

 

 

 

 

 

 

024

040

±

±

±

855

770

710

±

±

±

±

±

±

060

±

±

±

±

±

±

1020

890

835

±

±

±

 

030

040

±

±

±

880

840

805

±

±

±

±

±

±

060

±

±

±

±

±

±

1030

970

910

±

±

±

 

036

060

±

±

±

±

±

±

1035

995

955

±

±

±

090

±

±

±

±

±

±

±

±

±

1170

1110

1025

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ð24Ð

Image 24
Contents installation, start-up ICM FIOP INSTALLATION INSTRUCTIONSTABLE OF CONTENTS SAFETY CONSIDERATIONSRECEIVING AND INSTALLATION C. Easy SelectÐ583BINTRODUCTION ICM FIOP PRE-START-UP I. ELECTRICAL CONNECTIONSCONFIGURATION should be used when the rated ARI perfor For Gas Heat/Electric Cool Unit±AC must be selectedFig. 4Ð702B High- and Control-Voltage Connections Fig. 5Ð602B High- and Control-Voltage ConnectionsFig. 6ÐHumidifier Wiring-583B Fig. 7ÐHumidistat Wiring for De-Humidify Mode-583BD. 583B Sequence of Operation E. Easy SelectÐ683B Fig. 8ÐDetail of SPP Printed-Circuit BoardHUM G HUMIDIFIER WIRING Fig. 9ÐHumidifier Wiring-683BFig. 10ÐThermidistat Wiring for De-Humidify Mode-683B THERMIDISTATEASY SELECT CONFIGURATION TAPS FOR 702B & 602B F. 683B Sequence of OperationFig. 11ÐDetail of SPP Printed-Circuit Board 1. LO speedÐFactory setting, 50 percent cooling mode airflow Ð8Ð The type of system will be factory selected see below for details1. AC-Air conditioner Factory Selected for 702B 3. SYSTEM TYPE-Factory selected AC 702B or HP-EFF 602BFig. 12ÐHumidifier Wiring for 702B & 602B Fig. 13ÐHumidistat Wiring for De-Humidify Mode-for 702B & 602BH. 702B & 602B Sequence Of Operation ICM FIOP START-UP ICM General Start UpI. 583B START-UP ICM FIOP II. 683B START-UP ICM FIOPIII. 702B START-UP ICM FIOP IV. 602B START-UP ICM FIOP2. Thermostat Thermidistat or Thermostat and HumidistatELECTRICAL DATA & SCHEMATICSÐICM FIOP I. PHYSICAL DATA & ELECTRICAL SCHEMATICSCARE AND MAINTENANCE TABLE 1ÐICM FIOP PHYSICAL DATAÐUNIT 583BTROUBLESHOOTING START-UP CHECKLIST TABLE 2ÐICM FIOP PHYSICAL DATAÐUNIT 583B CONTINUEDTABLE 3Ð583B WITH ICM FIOP ELECTRICAL DATA Fig. 14ÐICM FIOP Electric SchematicÐUnit 583B Ð14ÐTABLE 4ÐICM FIOP PHYSICAL DATAÐUNIT 683B Ð15ÐTABLE 5ÐICM FIOP PHYSICAL DATAÐUNIT 683B CONTINUED TABLE 6Ð683B WITH ICM FIOP ELECTRICAL DATAÐ16Ð Fig. 15ÐICM FIOP Electric SchematicÐUnit 683B Ð17ÐTABLE 7ÐICM FIOP PHYSICAL DATAÐUNIT 702B Ð18ÐTABLE 8Ð702B WITH ICM FIOP ELECTRICAL DATA Ð19ÐFig. 16ÐICM FIOP Electrical SchematicÐ702B Ð20ÐTABLE 9ÐICM FIOP PHYSICAL DATAÐUNIT 602B Ð21ÐTABLE 10Ð602B WITH ICM FIOP ELECTRICAL DATA Ð22ÐFig. 17ÐICM FIOP Electrical SchematicÐ602B Ð23ÐTABLE 11±583B & 683B COOLING AND HEAT PUMP HEATING-683B ONLY DRY COIL ICM AIRFLOW SMALL CABINETTABLE 12Ð583B & 683B COOLING AND HEAT PUMP HEATING-683B ONLY DRY COIL ICM AIRFLOW LARGE CABINETTABLE 14Ð583B & 683B GAS HEATING ICM AIRFLOW LARGE CABINET TABLE 15Ð583B & 683B ICM AIR FLOW VS. TEMPERATURE RISE CHARTTABLE 16Ð702B/602B COOLING & HEATING DRY COIL ICM AIRFLOW SMALL CABINETTABLE 17Ð702B/602B COOLING & HEATING DRY COIL ICM AIRFLOW LARGE CABINETTABLE 18ÐMINIMUM AIRFLOW FOR RELIABLE ELECTRIC HEATER OPERATION CFM TABLE 19ÐELECTRIC HEAT PRESSURE DROP TABLE IN. WG SMALL CABINETTABLE 21ÐICM FIOP WET COIL PRESSURE DROP IN. WG TABLE 22ÐFILTER PRESSURE DROP TABLE IN. WGTABLE 23ÐELECTRIC HEATER MULTIPLICATION FACTORS Ð27ÐTHERMIDISTAT CONTROL SETTINGS TABLE 24ÐTROUBLESHOOTING CHARTQUICK REFERENCE GUIDE SET-UP INSTRUCTIONS FOR WARMER HEATING TEMPERATURESSTART-UP CHECKLIST Remove and Store in Job File IV. EASY SELECT SETTINGSEASY SELECT I. Preliminary InformationÐ30Ð Printed in U.S.Aii583b243 Catalog No
Related manuals
Manual 30 pages 21.04 Kb Manual 28 pages 39.19 Kb

602B, 683B, 702B, 583B specifications

The Bryant 583B is an advanced, high-efficiency gas furnace designed to provide exceptional heating performance and reliability. With a focus on comfort and energy efficiency, this model stands out in the residential heating market.

One of the main features of the Bryant 583B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%. This means that the furnace converts up to 95% of the fuel it consumes into usable heat. As a result, homeowners can expect lower energy bills and reduced environmental impact due to decreased carbon emissions.

The Bryant 583B is equipped with a modulating gas valve that allows for precise control of the heating output. This technology enables the furnace to adjust its running capacity based on the heating demands of your home. Instead of operating at a single, high setting, the furnace runs at the required level to maintain the desired temperature, delivering consistent comfort while maximizing efficiency.

Another noteworthy characteristic of the 583B is its two-stage operation. This feature allows the furnace to operate at a lower stage for mild weather, which reduces energy consumption and minimizes noise levels. During colder conditions, it can switch to a high stage for increased heating capacity. This dual approach not only enhances comfort but also prolongs the lifespan of the unit by reducing wear and tear.

In terms of construction, the Bryant 583B is built with durable materials and a robust cabinet, which ensures longevity and resilience over time. It also comes with a quiet operation feature, minimizing disturbances while maintaining a comfortable indoor environment.

The unit is compatible with Bryant's advanced communication technology, enabling seamless integration with smart thermostats. This addition allows homeowners to monitor and control their furnace remotely, optimizing energy usage even further.

In summary, the Bryant 583B furnishes an outstanding combination of efficiency, reliability, and user-friendly technologies. Its modulating gas valve, two-stage operation, and high AFUE rating collectively ensure that customers enjoy a comfortable home environment while significantly reducing energy costs. As energy-conscious choices become increasingly crucial, the Bryant 583B stands ready to meet the challenges of modern heating needs.