Bryant 702B, 683B ÐICM FIOP PHYSICAL DATAÐUNIT 583B, Electrical Data & Schematicsðicm Fiop

Page 12

TABLE 1ÐICM FIOP PHYSICAL DATAÐUNIT 583B

THIS DATA APPLIES TO 583B UNITS WITH THE ICM INDOOR MOTOR FIOP

UNIT SIZE 583B

024040

024060

030040

030060

 

036060

036090

042060

042090

NOMINAL CAPACITY (ton)

2

2

2-1/2

2-1/2

 

3

3

3-1/2

3-1/2

OPERATING WEIGHT (lb.)

290

290

313

313

 

321

321

382

382

COMPRESSORS

 

 

 

Scroll

 

 

 

Quantity

 

 

 

 

1

 

 

 

REFRIGERANT (R-410A)

5.0

5.0

5.5

5.5

 

6.9

6.9

9.0

9.0

Quantity (lb.)

 

 

 

 

 

 

 

 

 

 

REFRIGERANT METERING DEVICE

 

 

 

 

 

 

 

 

 

Orifice ID (in.)

.057

.057

.057

.057

 

.065

.065

.070

.070

Check-Flo-Rater™ Piston

 

 

 

 

 

 

 

 

 

CONDENSER COIL

1...17

1...17

1...17

1...17

 

2...17

2...17

2...17

2...17

Rows...Fins/in.

 

10.9

10.9

12.7

12.7

 

9.1

9.1

12.3

12.3

Face Area (sq ft)

 

 

 

 

 

 

 

 

 

 

CONDENSER FAN

2350

2350

2350

2350

 

2350

2350

2350

2350

Nominal Cfm

 

22

22

22

22

 

22

22

22

22

Diameter (in.)

 

1/8 (825)

1/8 (825)

1/8 (825)

1/8 (825)

 

1/8 (825)

1/8 (825)

1/8 (825)

1/8 (825)

Motor HP (Rpm)

 

 

 

 

 

 

 

 

 

 

EVAPORATOR COIL

3...15

3...15

3...15

3...15

 

3...15

3...15

3...15

3...15

Rows...Fins/in.

 

3.7

3.7

3.7

3.7

 

3.7

3.7

4.7

4.7

Face Area (sq ft)

 

 

 

 

 

 

 

 

 

 

EVAPORATOR BLOWER

800

800

1000

1000

 

1200

1200

1400

1400

Nominal Airflow (Cfm)

 

10 X 10

10 X 10

10 X 10

10 X 10

 

11 X 10

11 X 10

11 X 10

11 X 10

Size (in.)

 

1/2

1/2

1/2

1/2

 

3/4

3/4

3/4

3/4

Motor (HP)

 

 

 

 

 

 

 

 

 

 

FURNACE SECTION*

 

 

 

 

 

 

 

 

 

Burner Orifice No. (Qty...Drill Size)

2...44

2...38

2...44

2...38

 

2...38

3...38

2...38

3...38

Natural Gas

 

2...50

2...46

2...50

2...46

 

2...46

3...46

2...46

3...46

Burner Orifice No. (Qty...Drill Size)

 

 

 

 

 

 

 

 

 

 

Propane Gas

 

 

 

 

 

 

 

 

 

HIGH-PRESSURE SWITCH (psig)

 

 

 

610 ± 15

 

 

 

Cutout

 

 

 

 

 

 

 

 

 

420 ± 25

 

 

 

Reset (Auto)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOSS-OF-CHARGE/LOW-

 

 

 

 

 

 

 

 

 

PRESSURE SWITCH

 

 

 

20 ± 5

 

 

 

(Liquid Line) (psig)

 

 

 

 

 

 

 

 

 

45 ± 10

 

 

 

Cutout

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset (Auto)

 

 

 

 

 

 

 

 

 

RETURN-AIR FILTERS (in.)

20 X 20 X 1

20 X 20 X 1

20 X 20 X 1

20 X 20 X 1

 

20 X 24 X 1

20 X 24 X 1

24 X 30 X 1

24 X 30 X 1

Throwaway

 

 

 

 

 

 

 

 

 

 

* Based on altitude of 0 to 2000 ft.

blower motor stops. The unit is in a ``standby'' condition, waiting for the next ``call for cooling'' from the room thermostat. The 5 minute compressor delay also applies to heat pump heating mode.

ELECTRICAL DATA & SCHEMATICSÐICM FIOP

I.PHYSICAL DATA & ELECTRICAL SCHEMATICS

Use the Physical Data and Electrical Tables on the following pages for information that applies to Bryant Puron® units with the ICM indoor motor FIOP.

AIRFLOW & TEMPERATURE RISE TABLESÐICM

FIOP

II.TABLES FOR SYSTEM SET-UP

Use the Airflow and Temperature Rise Tables on the following pages for information that applies to Bryant Puron® units with the ICM indoor motor FIOP.

CARE AND MAINTENANCE

Indoor Blower and Motor

NOTE: All motors are pre-lubricated. Do not attempt to lubricate these motors. For longer life, operating economy, and continuing efficiency, clean accumulated dirt and grease from the blower wheel and motor annually.

Ð12Ð

WARNING: Disconnect and tag electrical power to the unit before cleaning and lubricating any blower motor and wheel. On units with gas heat, turn off the gas supply before disconnecting the electrical power. Failure to adhere to this warning could cause serious injury or death.

To clean the blower motor and wheel:

1.1. Remove and disassemble blower assembly as follows:

a.Remove unit access panel.

b.Carefully pivot blower access panel outward towards the electrical box. Route wiring above blower access panel.

c.Disconnect the 5 and 16 pin plugs at the blower motor.

d.On all units, remove blower assembly from unit. Re- move screws securing blower to vertical partition and slide assembly out. Be careful not to tear insulation in blower compartment.

e.Ensure proper reassembly by marking blower wheel and motor in relation to blower housing before disassembly.

Image 12
Contents installation, start-up ICM FIOP INSTALLATION INSTRUCTIONSTABLE OF CONTENTS SAFETY CONSIDERATIONSRECEIVING AND INSTALLATION C. Easy SelectÐ583BINTRODUCTION ICM FIOP PRE-START-UP I. ELECTRICAL CONNECTIONSCONFIGURATION should be used when the rated ARI perfor For Gas Heat/Electric Cool Unit±AC must be selectedFig. 4Ð702B High- and Control-Voltage Connections Fig. 5Ð602B High- and Control-Voltage ConnectionsFig. 6ÐHumidifier Wiring-583B Fig. 7ÐHumidistat Wiring for De-Humidify Mode-583BD. 583B Sequence of Operation E. Easy SelectÐ683B Fig. 8ÐDetail of SPP Printed-Circuit BoardHUM G HUMIDIFIER WIRING Fig. 9ÐHumidifier Wiring-683BFig. 10ÐThermidistat Wiring for De-Humidify Mode-683B THERMIDISTATEASY SELECT CONFIGURATION TAPS FOR 702B & 602B F. 683B Sequence of OperationFig. 11ÐDetail of SPP Printed-Circuit Board 1. LO speedÐFactory setting, 50 percent cooling mode airflow Ð8Ð The type of system will be factory selected see below for details1. AC-Air conditioner Factory Selected for 702B 3. SYSTEM TYPE-Factory selected AC 702B or HP-EFF 602BFig. 12ÐHumidifier Wiring for 702B & 602B Fig. 13ÐHumidistat Wiring for De-Humidify Mode-for 702B & 602BH. 702B & 602B Sequence Of Operation ICM FIOP START-UP ICM General Start UpI. 583B START-UP ICM FIOP II. 683B START-UP ICM FIOPIII. 702B START-UP ICM FIOP IV. 602B START-UP ICM FIOP2. Thermostat Thermidistat or Thermostat and HumidistatELECTRICAL DATA & SCHEMATICSÐICM FIOP I. PHYSICAL DATA & ELECTRICAL SCHEMATICSCARE AND MAINTENANCE TABLE 1ÐICM FIOP PHYSICAL DATAÐUNIT 583BTROUBLESHOOTING START-UP CHECKLIST TABLE 2ÐICM FIOP PHYSICAL DATAÐUNIT 583B CONTINUEDTABLE 3Ð583B WITH ICM FIOP ELECTRICAL DATA Fig. 14ÐICM FIOP Electric SchematicÐUnit 583B Ð14ÐTABLE 4ÐICM FIOP PHYSICAL DATAÐUNIT 683B Ð15ÐTABLE 5ÐICM FIOP PHYSICAL DATAÐUNIT 683B CONTINUED TABLE 6Ð683B WITH ICM FIOP ELECTRICAL DATAÐ16Ð Fig. 15ÐICM FIOP Electric SchematicÐUnit 683B Ð17ÐTABLE 7ÐICM FIOP PHYSICAL DATAÐUNIT 702B Ð18ÐTABLE 8Ð702B WITH ICM FIOP ELECTRICAL DATA Ð19ÐFig. 16ÐICM FIOP Electrical SchematicÐ702B Ð20ÐTABLE 9ÐICM FIOP PHYSICAL DATAÐUNIT 602B Ð21ÐTABLE 10Ð602B WITH ICM FIOP ELECTRICAL DATA Ð22ÐFig. 17ÐICM FIOP Electrical SchematicÐ602B Ð23ÐTABLE 11±583B & 683B COOLING AND HEAT PUMP HEATING-683B ONLY DRY COIL ICM AIRFLOW SMALL CABINETTABLE 12Ð583B & 683B COOLING AND HEAT PUMP HEATING-683B ONLY DRY COIL ICM AIRFLOW LARGE CABINETTABLE 14Ð583B & 683B GAS HEATING ICM AIRFLOW LARGE CABINET TABLE 15Ð583B & 683B ICM AIR FLOW VS. TEMPERATURE RISE CHARTTABLE 16Ð702B/602B COOLING & HEATING DRY COIL ICM AIRFLOW SMALL CABINETTABLE 17Ð702B/602B COOLING & HEATING DRY COIL ICM AIRFLOW LARGE CABINETTABLE 18ÐMINIMUM AIRFLOW FOR RELIABLE ELECTRIC HEATER OPERATION CFM TABLE 19ÐELECTRIC HEAT PRESSURE DROP TABLE IN. WG SMALL CABINETTABLE 21ÐICM FIOP WET COIL PRESSURE DROP IN. WG TABLE 22ÐFILTER PRESSURE DROP TABLE IN. WGTABLE 23ÐELECTRIC HEATER MULTIPLICATION FACTORS Ð27ÐTHERMIDISTAT CONTROL SETTINGS TABLE 24ÐTROUBLESHOOTING CHARTQUICK REFERENCE GUIDE SET-UP INSTRUCTIONS FOR WARMER HEATING TEMPERATURESSTART-UP CHECKLIST Remove and Store in Job File IV. EASY SELECT SETTINGSEASY SELECT I. Preliminary InformationÐ30Ð Printed in U.S.Aii583b243 Catalog No
Related manuals
Manual 30 pages 21.04 Kb Manual 28 pages 39.19 Kb

602B, 683B, 702B, 583B specifications

The Bryant 583B is an advanced, high-efficiency gas furnace designed to provide exceptional heating performance and reliability. With a focus on comfort and energy efficiency, this model stands out in the residential heating market.

One of the main features of the Bryant 583B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%. This means that the furnace converts up to 95% of the fuel it consumes into usable heat. As a result, homeowners can expect lower energy bills and reduced environmental impact due to decreased carbon emissions.

The Bryant 583B is equipped with a modulating gas valve that allows for precise control of the heating output. This technology enables the furnace to adjust its running capacity based on the heating demands of your home. Instead of operating at a single, high setting, the furnace runs at the required level to maintain the desired temperature, delivering consistent comfort while maximizing efficiency.

Another noteworthy characteristic of the 583B is its two-stage operation. This feature allows the furnace to operate at a lower stage for mild weather, which reduces energy consumption and minimizes noise levels. During colder conditions, it can switch to a high stage for increased heating capacity. This dual approach not only enhances comfort but also prolongs the lifespan of the unit by reducing wear and tear.

In terms of construction, the Bryant 583B is built with durable materials and a robust cabinet, which ensures longevity and resilience over time. It also comes with a quiet operation feature, minimizing disturbances while maintaining a comfortable indoor environment.

The unit is compatible with Bryant's advanced communication technology, enabling seamless integration with smart thermostats. This addition allows homeowners to monitor and control their furnace remotely, optimizing energy usage even further.

In summary, the Bryant 583B furnishes an outstanding combination of efficiency, reliability, and user-friendly technologies. Its modulating gas valve, two-stage operation, and high AFUE rating collectively ensure that customers enjoy a comfortable home environment while significantly reducing energy costs. As energy-conscious choices become increasingly crucial, the Bryant 583B stands ready to meet the challenges of modern heating needs.