Heatiator IDV4833IT Vent Information and Diagrams, A. Approved Pipe, B. Vent Table Key

Models: IDV4833IT

1 60
Download 60 pages 45.55 Kb
Page 22
Image 22
7 Vent Information and Diagrams

7 Vent Information and Diagrams

A. Approved Pipe

This appliance is approved for use with Hearth & Home Technologies DVP venting systems. Refer to Section 16.B. for vent component information.

DO NOT mix pipe, fittings or joining methods from differ- ent manufacturers.

The pipe is tested to be run inside an enclosed wall. There is no requirement for inspection openings at each joint within the wall.

WARNING! Risk of Fire or Asphyxiation. This appliance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance.

B. Vent Table Key

The abbreviations listed in this vent table key are used in the vent diagrams.

Symbol

Description

 

 

V1

First section (closest to appliance) of vertical length

 

 

V2

Second section of vertical length

 

 

H1

First section (closest to appliance) of horizontal length

 

 

H2

Subsequent sections of horizontal length

 

 

C. Use of Elbows

Diagonal runs have both vertical and horizontal vent aspects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect (see Figure 7.1).

Two 45º elbows may be used in place of one 90º elbow. On 45º runs, one foot of diagonal is equal to 8-1/2 in. (216

mm)horizontal run and 8-1/2 in. (216 mm) vertical run. A length of straight pipe is allowed between two 45º elbows (see Figure 7.1).

D. Measuring Standards

Vertical and horizontal measurements listed in the vent diagrams were made using the following standards.

Pipe measurements are shown using the effective length of pipe (see Figure 7.2).

Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Figure 6.1).

Vertical terminations are measured to bottom of termination cap.

Horizontal pipe installed level with no rise.

Vertical

 

 

in.

 

 

.

1/2-8

 

12

in

 

 

 

 

 

8-1/2 in.

 

A. Approved PipeB. Vent Table Key Horizontal C. Use of Elbows

On 45° runs, 1 ft (.3 m) of diagonal is equal to 8-1/2 in. (216 mm) horizontal run and 8-1/2 in. (216 mm) vertical run.

Figure 7.1 Using Two 45° Elbows

 

 

 

 

 

 

 

 

 

 

 

 

Effective Height/Length

 

 

 

 

 

 

 

 

 

 

 

 

Pipe

inches

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DVP4

4

102

 

 

 

 

 

 

 

 

 

 

 

 

DVP6

6

152

 

 

 

 

 

 

 

 

Effective

 

 

 

 

 

 

 

 

 

DVP12

12

305

 

 

 

 

 

 

Height/Length

 

 

 

 

 

 

 

 

DVP24

24

610

 

 

 

 

 

 

 

 

 

 

 

 

DVP36

36

914

 

 

 

 

 

 

 

 

 

 

 

 

DVP48

48

1219

 

 

 

 

 

 

 

 

 

 

 

 

DVP6A

3 - 6

76 - 152

 

 

 

 

 

 

 

 

 

 

 

 

DVP12A

3 - 12

76 - 305

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DVP Pipe

(see chart)

Figure 7.2 Pipe Effective Length

22

Heatilator • ICON DV-IDV Series • 4042-575 • Rev. S • 5/11

Page 22
Image 22
Heatiator IDV4833IT owner manual Vent Information and Diagrams, A. Approved Pipe, B. Vent Table Key, C. Use of Elbows