Heatiator IDV4833IT E. Junction Box Installation, NOTICE: DO NOT wire 110 VAC to wall switch

Models: IDV4833IT

1 60
Download 60 pages 45.55 Kb
Page 42
Image 42
E. Junction Box Installation

E. Junction Box Installation

If the junction box is being wired from OUTSIDE of the appliance (preferred method):

Remove two screws that attach junction box and bracket to appliance. See Figure 13.2.

Feed an appropriate length of romex through plastic romex connector.

Make necessary electrical connections.

Attach outlet and cover plate to junction box.

Reattach junction box and bracket to appliance with two screws.

If the junction box is being wired from the INSIDE of the appliance:

Remove one screw that attaches access panel to column. See Figure 13.3.

Remove two screws that attach junction box to junction box bracket. See Figure 13.4.

Feed an appropriate length of romex through plastic romex connector.

Reattach junction box to junction box bracket with two screws.

Make necessary electrical connections.

Attach outlet and cover plate to junction box.

Reattach cover plate to column with one screw.

NOTICE: DO NOT wire 110 VAC to wall switch.

Figure 13.2 Remove Two Screws From Bracket

Figure 13.3 Remove Access Panel Screw

Figure 13.4 Remove Two Screws Holding Junction Box

42

Heatilator • ICON DV-IDV Series • 4042-575 • Rev. S • 5/11

Page 42